ICD-10-PCS Billable Code

0413493

Bypass Hepatic Artery to Renal Artery, Right with Autologous Venous Tissue, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System4 Lower Arteries
Operation1 Bypass
Body Part3 Hepatic Artery
Approach4 Percutaneous Endoscopic
Device9 Autologous Venous Tissue
Qualifier3 Renal Artery, Right

Operation Definition

Altering the route of passage of the contents of a tubular body part

Procedure Overview

Bypass procedures on the lower arteries create an alternate route for blood flow around a blocked or narrowed segment of an artery in the pelvis or legs, using either a graft made from the patient's own vein, a synthetic conduit, or another vessel repurposed for the route. The original diseased segment of the artery is left in place, and the new pathway carries blood around it to restore circulation to tissue downstream.

This surgery is most often performed to treat peripheral artery disease, where plaque buildup has significantly narrowed or blocked an artery in the leg and is causing pain, non-healing wounds, or tissue at risk of loss. Common examples include femoral-popliteal bypass and aortofemoral bypass, both of which reroute blood flow around blocked segments to preserve limb viability. Patients undergoing lower artery bypass typically have advanced atherosclerosis, often with a history of claudication, rest pain, or gangrene that has not responded to less invasive treatment.

Anatomy & Axis Detail

Hepatic Artery

The hepatic artery supplies oxygenated blood to the liver and, in many patients, to structures like the gallbladder and portions of the stomach and pancreas via its branches, making it a target for bypass when stenosis or occlusion threatens hepatic perfusion or when reconstruction is needed after tumor resection or transplant complications. Because the liver also receives substantial portal venous inflow, hepatic artery compromise does not always cause immediate infarction, but bypass is pursued when arterial supply is critical, such as in liver transplantation where hepatic artery thrombosis can jeopardize graft survival. The graft is anastomosed from a donor vessel, often the aorta or a branch of the celiac axis, to a patent segment beyond the diseased or injured hepatic artery. Precise identification of the inflow source is documented since it determines the applicable qualifier.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Autologous Venous Tissue

Autologous Venous Tissue describes a vein harvested from the patient's own body, commonly the saphenous vein, and used as a graft or conduit elsewhere in the same patient, as in coronary or peripheral bypass. Being autologous, it avoids rejection risk associated with donor or synthetic material, and it is distinguished from Autologous Arterial Tissue by originating from venous rather than arterial vasculature.

Qualifier: Renal Artery, Right

Specifies the right renal artery as the treated vessel, commonly for angioplasty or stenting in renal artery stenosis affecting blood pressure control or kidney function. Laterality separates it from the left-sided qualifier, and both are distinguished from the bilateral qualifier used when both renal arteries are addressed in the same encounter. It should reflect exactly which kidney's supplying artery was accessed.

Coding & Documentation

Coding a bypass procedure requires documentation identifying both the origin and the target of the new route, since the body part value captures where blood flow is coming from and the qualifier captures where it is being routed to. The operative note must also specify the type of conduit used, whether autologous vein, synthetic graft, or another vessel, since this determines the correct device value.

A common assignment error is failing to correctly identify the bypass target when a graft crosses multiple named arterial segments, leading to a code that reflects the wrong destination vessel. Coders also frequently miss that when a bypass procedure includes work on more than one arterial segment, such as a sequential bypass supplying multiple distal targets, each distinct bypass may need its own code rather than being captured under a single entry.

Commonly Confused With

DilationBypass is commonly confused with Dilation, since both restore blood flow through a diseased segment, but dilation widens the existing artery from within using angioplasty or stenting while bypass creates an entirely separate route around the diseased portion.
RestrictionIt is also confused with Restriction or Occlusion when a bypass procedure is performed alongside ligation of the diseased native vessel, which requires a separate code for the additional root operation.
RepositionReposition can be confused with bypass in cases involving vessel transposition, but reposition relocates the native artery itself rather than adding a new conduit alongside it.