ICD-10-PCS Billable Code

0T760DZ

Dilation Ureter, Right to No Qualifier with Intraluminal Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemT Urinary System
Operation7 Dilation
Body Part6 Ureter, Right
Approach0 Open
DeviceD Intraluminal Device
QualifierZ No Qualifier

Operation Definition

Expanding an orifice or the lumen of a tubular body part

Procedure Overview

Dilation procedures widen a narrowed segment of the urinary tract, most often the ureter, urethra, or bladder neck, to restore normal urine flow through the existing channel. Balloon dilation of a ureteral stricture or urethral dilation for a post-surgical narrowing are typical examples, frequently performed under cystoscopic or fluoroscopic guidance.

Strictures develop from prior surgery, radiation, chronic catheterization, trauma, or scarring, and if left untreated can cause pain, recurrent infection, or kidney injury from obstructed drainage. Dilation offers a less invasive alternative to reconstructive surgery, though some strictures recur and require repeat treatment or an eventual bypass or repair.

Anatomy & Axis Detail

Ureter, Right

The right ureter can develop strictures from prior stone passage, surgical injury, radiation, or malignancy, and dilation is used to restore its caliber when narrowing impedes urinary drainage. A guidewire is passed retrograde through a cystoscope and up the ureter, over which balloon or coaxial dilators are advanced to stretch the stenotic segment, typically followed by stent placement to maintain the newly opened lumen. Because the right ureter crosses beneath the gonadal vessels and near the appendix, prior abdominal or pelvic surgery on that side is a common contributor to acquired strictures requiring this intervention. Coders should note that dilation addresses the narrowed lumen itself and is distinct from destruction of tissue causing obstruction, and that repeat dilations are common when strictures are fibrotic and prone to recurrence.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Intraluminal Device

Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.

Coding & Documentation

Coding depends on confirming that the procedure expanded an existing orifice or lumen without creating a new passage or removing tissue; the device value also matters, since a stent or balloon left temporarily in place changes the code. Documentation should specify the exact site dilated, as ureteral, urethral, and bladder-neck dilations use different body part values. A common mistake is coding Dilation when a stricture was actually incised (Division) or excised, rather than mechanically stretched, or overlooking that an intraluminal device was left behind.

Commonly Confused With

BypassDilation is commonly confused with Bypass, since both address obstruction, but Dilation restores the original channel rather than creating a new route.
DivisionIt is also distinct from Division, which involves cutting through a restricting band rather than stretching the passage open.