ICD-10-PCS Billable Code

0T787ZZ

Dilation Ureters, Bilateral to No Qualifier with No Device, Via Natural or Artificial Opening Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemT Urinary System
Operation7 Dilation
Body Part8 Ureters, Bilateral
Approach7 Via Natural or Artificial Opening
DeviceZ No Device
QualifierZ No Qualifier

Operation Definition

Expanding an orifice or the lumen of a tubular body part

Procedure Overview

Dilation procedures widen a narrowed segment of the urinary tract, most often the ureter, urethra, or bladder neck, to restore normal urine flow through the existing channel. Balloon dilation of a ureteral stricture or urethral dilation for a post-surgical narrowing are typical examples, frequently performed under cystoscopic or fluoroscopic guidance.

Strictures develop from prior surgery, radiation, chronic catheterization, trauma, or scarring, and if left untreated can cause pain, recurrent infection, or kidney injury from obstructed drainage. Dilation offers a less invasive alternative to reconstructive surgery, though some strictures recur and require repeat treatment or an eventual bypass or repair.

Anatomy & Axis Detail

Ureters, Bilateral

Bilateral ureteral dilation is coded when both ureters are widened in the same operative episode, most often for symmetric strictures caused by retroperitoneal fibrosis, radiation therapy, or extensive pelvic malignancy compressing both tubes. Each ureter is separately catheterized and dilated using balloon or mechanical dilators, generally followed by bilateral stent placement, and the procedure is more involved than a single-side dilation because both renal units are at risk of obstruction if either side fails to open adequately. This bilateral pattern often signals a systemic or centrally located process rather than a focal, one-sided injury, which can inform how the underlying cause is worked up. Documentation should confirm that both ureters were addressed with dilation during the same procedural session to support use of the bilateral body part value rather than reporting two separate unilateral codes.

Approach: Via Natural or Artificial Opening

Via Natural or Artificial Opening means the instrument reaches the target site by passing through an existing body orifice, such as the mouth or urethra, or a surgically created opening like a stoma, without additional incision or scope guidance. It is distinguished from the Endoscopic variant by the absence of a visualizing scope, and from External by actually traversing into the body through that opening.

Coding & Documentation

Coding depends on confirming that the procedure expanded an existing orifice or lumen without creating a new passage or removing tissue; the device value also matters, since a stent or balloon left temporarily in place changes the code. Documentation should specify the exact site dilated, as ureteral, urethral, and bladder-neck dilations use different body part values. A common mistake is coding Dilation when a stricture was actually incised (Division) or excised, rather than mechanically stretched, or overlooking that an intraluminal device was left behind.

Commonly Confused With

BypassDilation is commonly confused with Bypass, since both address obstruction, but Dilation restores the original channel rather than creating a new route.
DivisionIt is also distinct from Division, which involves cutting through a restricting band rather than stretching the passage open.