ICD-10-PCS Billable Code

07DT0ZZ

Extraction Bone Marrow to No Qualifier with No Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System7 Lymphatic and Hemic Systems
OperationD Extraction
Body PartT Bone Marrow
Approach0 Open
DeviceZ No Device
QualifierZ No Qualifier

Operation Definition

Pulling or stripping out or off all or a portion of a body part by the use of force

Procedure Overview

Extraction in this body system almost always refers to bone marrow procedures - pulling out marrow tissue using a needle and manual force rather than a cutting instrument. A physician advances a needle into the marrow cavity, usually at the posterior iliac crest, and withdraws either a liquid marrow sample by aspiration or a solid core sample by twisting and pulling the needle free.

These procedures are performed to evaluate blood cell production when someone has unexplained anemia, abnormal blood counts, a suspected blood cancer, or to stage lymphoma. The same technique, at larger volume, is used to harvest marrow for a stem cell or bone marrow transplant, where the marrow is collected from a donor rather than for diagnosis.

Because the tissue is pulled or stripped out by force rather than sliced away, this family sits apart from ordinary biopsy techniques used on solid organs, even though the clinical intent, sampling tissue for evaluation, is similar.

Anatomy & Axis Detail

Bone Marrow

This unspecified bone marrow designation applies when marrow tissue is sampled without documentation tying the procedure to a particular skeletal site such as the iliac crest, sternum, or a vertebra. Extraction pulls marrow cells or a core of marrow tissue free using an aspiration or biopsy needle, most often to evaluate cytopenias, suspected leukemia or lymphoma, or to stage a hematologic malignancy already identified elsewhere. Because bone marrow composition and accessibility vary meaningfully by location, coders should treat this general value as a fallback used only when the operative note genuinely does not specify the site sampled, rather than defaulting to it out of convenience when a more precise body part value is documented.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Coding & Documentation

Coders need documentation specifying whether the procedure was a marrow aspiration (liquid marrow withdrawn by syringe), a core biopsy (a solid cylinder of marrow pulled out with a biopsy needle), or both, since both are captured under Extraction but the approach and diagnostic qualifier may differ. The note should confirm the bone marrow was the target, not a separate skeletal structure, since a bone biopsy with marrow incidentally obtained is coded differently.

A common mistake is defaulting to Excision because the word "biopsy" appears in the note; bone marrow biopsy is Extraction by PCS definition regardless of that word choice. Another error is failing to separately code an aspiration and a core biopsy performed at the same session through two separate needle passes, when guidelines call for capturing both.

Commonly Confused With

ExcisionExcision is the term coders reflexively reach for with any biopsy, but marrow sampling is defined as Extraction because the tissue is physically pulled free rather than cut.
DrainageDrainage is sometimes confused with marrow aspiration since both involve a needle and a syringe, but drainage removes fluid that has abnormally accumulated, while aspiration pulls normal marrow tissue for sampling.
InsertionInsertion of a bone marrow harvest device is a separate, uncommon consideration only if a mechanical harvesting system rather than manual extraction is used.