0SG937Z
Fusion Hip Joint, Right to No Qualifier with Autologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | G Fusion |
| Body Part | 9 Hip Joint, Right |
| Approach | 3 Percutaneous |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Joining together portions of an articular body part rendering the articular body part immobile
Procedure Overview
Fusion, also called arthrodesis, permanently joins the bones of a lower joint so that the joint can no longer move, converting a painful or unstable joint into a solid, stable one. It is used on the hip, knee, ankle, foot, and lumbar or lumbosacral spinal joints for conditions like severe arthritis, joint instability, failed prior surgery, deformity correction, or chronic pain that has not responded to less invasive treatment. Hardware such as screws, plates, or rods, sometimes combined with a bone graft, holds the joint surfaces together while they grow into one continuous piece of bone.
Because fusion eliminates motion at the treated joint, it is generally considered after other options such as medication, injections, or partial procedures have failed to control symptoms. Spinal fusion in the lumbar region is one of the most common examples, performed for conditions like degenerative disc disease, spondylolisthesis, or spinal instability.
Recovery typically takes several months as the bone heals across the joint, and patients can expect a trade of joint mobility for pain relief and structural stability.
Anatomy & Axis Detail
Hip Joint, Right
The right hip joint is a ball-and-socket articulation between the femoral head and the acetabulum, and fusion here, hip arthrodesis, is now an uncommon salvage procedure reserved for younger patients with severe post-traumatic arthritis, infection, or failed prior surgery in whom joint replacement is not favored due to activity demands or infection risk. The procedure permanently eliminates hip motion by achieving bony union between the femoral head and acetabulum, often using plate and screw fixation or intramedullary devices to hold the joint in a functional position for standing and walking. Because the hip is central to gait, limb positioning at the time of fusion is critical, and even small malalignment can produce compensatory strain on the lumbar spine and knee. Documentation should note the fixation device and any structural graft used to promote union.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
Coders need documentation confirming that articular surfaces were joined with the intent of eliminating motion, along with the device used (bone graft substitute, autograft, nonautograft, or internal fixation) and, for spinal fusion, the number of vertebral joints involved, since each level typically requires its own code. A frequent error is under-coding multilevel spinal fusions by capturing only one joint level instead of each level fused. Another common mistake is confusing the qualifier for graft material, since autologous bone graft, synthetic substitute, and no-graft fixation all carry different qualifier values that materially change the code. Coders should also check whether an anterior and posterior approach were both performed at the same spinal level, which requires separate codes for each approach.