ICD-10-PCS Billable Code

0BHK02Z

Insertion Lung, Right to No Qualifier with Monitoring Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemB Respiratory System
OperationH Insertion
Body PartK Lung, Right
Approach0 Open
Device2 Monitoring Device
QualifierZ No Qualifier

Operation Definition

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Procedure Overview

This family covers procedures that place a nonbiological device into the airway or chest to support breathing or monitor respiratory status, without removing or replacing any of the patient's own tissue. The most familiar examples are placing an endotracheal tube through the mouth or nose into the trachea to secure an airway during surgery or critical illness, and inserting a tracheostomy tube through a surgical opening in the neck for patients who need longer-term airway support. A monitoring device may also be placed in the airway or lung to track pressures or gas exchange over time. These procedures are performed when a patient cannot maintain their own airway, needs mechanical ventilation, or requires ongoing respiratory monitoring, ranging from emergency intubation to planned tracheostomy for chronic ventilator dependence.

Anatomy & Axis Detail

Lung, Right

The right lung, comprising three lobes supplied by the right main bronchus, is the target when a device is placed directly into its parenchyma rather than the airway lumen. This typically means percutaneous or bronchoscopic placement of fiducial markers to guide stereotactic body radiotherapy for a peripheral tumor, or implantation of radioactive seeds for brachytherapy. Because the right lung sits close to the liver and has a shorter, more vertically oriented main bronchus than the left, image guidance (CT or fluoroscopy) is used to avoid the diaphragm and major vessels during placement. Documentation should specify the approach (percutaneous versus bronchoscopic) and confirm the device remains within lung tissue rather than the pleural space, distinguishing this procedure from insertion into the pleura itself.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Monitoring Device

Monitoring Device designates a device left in place to measure or track a physiologic parameter, such as an implanted pressure or activity sensor. It differs from Drainage Device, which removes fluid or air, by instead collecting data for ongoing clinical assessment without evacuating any substance from the body.

Coding & Documentation

Coders assign from this family when documentation describes placing a device without disturbing or excising native anatomy, and the device stays behind after the procedure ends. Operative notes should specify the device type (endotracheal tube, tracheostomy tube, monitoring device) and the body part entered, since that determines the qualifier and body part value. A frequent error is coding a tracheostomy tube exchange or routine reinsertion as Insertion when it should reflect the original placement versus a change, or confusing airway securement during anesthesia (not separately coded) with a therapeutic tracheostomy tube placement. Coders also sometimes miss that a percutaneous versus open tracheostomy approach changes the approach character even though the root operation stays the same.

Commonly Confused With

ReplacementInsertion is easily confused with Replacement, which is used when a device physically takes the place of a body part rather than simply being put into it; a tracheoesophageal voice prosthesis inserted into an existing puncture is Insertion, not Replacement.
DrainageIt also differs from Drainage, which targets fluid removal rather than device placement, even though a chest tube inserted for pleural drainage is coded to the Drainage root operation with a device value rather than to Insertion.