ICD-10-PCS Billable Code

06HP33Z

Insertion Saphenous Vein, Right to No Qualifier with Infusion Device, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System6 Lower Veins
OperationH Insertion
Body PartP Saphenous Vein, Right
Approach3 Percutaneous
Device3 Infusion Device
QualifierZ No Qualifier

Operation Definition

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Procedure Overview

Insertion in this family covers placing a nonbiological device into a lower extremity or lower abdominal vein that monitors, assists, or supports venous function without replacing the vein itself. The most common example is placement of an inferior vena cava filter, a small metal device designed to trap blood clots traveling from the legs before they reach the lungs, typically used in patients who cannot take blood thinners or who have had a clot despite being on them.

Other examples in this category include placing a venous catheter intended to remain in place for monitoring or infusion access through a lower extremity vein, or positioning a temporary device used to support venous flow during another procedure. The device stays in the vein to perform an ongoing function, distinguishing it from a one-time intervention like removing a clot or reshaping the vessel.

These procedures are usually done percutaneously under imaging guidance, with the physician threading the device through a peripheral vein access point to its target location in the venous system.

Anatomy & Axis Detail

Saphenous Vein, Right

The right saphenous vein, whether the great saphenous running from the medial ankle to the groin or the small saphenous along the posterior calf, is a superficial channel large and consistent enough to serve as a conduit for indwelling devices. Insertion here most often means placing an intraluminal appliance such as a peripherally inserted catheter, a temporary access sheath, or a closure/occlusion device introduced for later endovenous ablation, rather than removing or repairing diseased vein tissue. Because the vessel lies just beneath the skin and has a fairly predictable course, ultrasound guidance is commonly used to confirm patency and avoid the accompanying saphenous nerve. Documentation should specify the device left in place and distinguish this insertion from any concurrent vein stripping, ligation, or ablation procedure coded separately under a different root operation.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Infusion Device

Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.

Coding & Documentation

Coders should confirm that the documentation describes placing a device intended to stay in the vein and serve an ongoing monitoring, protective, or supportive function, such as an IVC filter, rather than a device used only during the procedure and then withdrawn. The specific vein and device type both need to be clear in the operative note, since filter placement in the inferior vena cava is coded differently depending on the exact body part value available.

A common error is coding Insertion for devices that are actually part of a different root operation, such as a stent used to hold a vein open, which is coded as Restriction or Dilation with a device value rather than a standalone Insertion. Coders should also watch for IVC filter retrieval performed later, which is a separate Removal procedure and not part of the original Insertion code, and should not be conflated with it even when both occur in the same patient's history.

Commonly Confused With

RestrictionRestriction and Dilation procedures that use a device, such as a venous stent placed to keep a narrowed vein open, are easily confused with Insertion because both leave hardware inside the vein, but the root operation is determined by what the device does: narrowing or supporting the lumen's shape belongs to Restriction or Dilation with a device value, while a device solely intended to filter, monitor, or otherwise perform a separate function without altering the vessel's diameter belongs to Insertion.
RemovalRemoval is the corresponding root operation used later if the inserted device, such as a retrievable IVC filter, is taken back out, and the two should never be coded together for the same encounter.