0XH201Z
Insertion Shoulder Region, Right to No Qualifier with Radioactive Element, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | X Anatomical Regions, Upper Extremities |
| Operation | H Insertion |
| Body Part | 2 Shoulder Region, Right |
| Approach | 0 Open |
| Device | 1 Radioactive Element |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Procedure Overview
This group covers placing a nonbiological device into an upper-extremity region without replacing any body part - most often an external fixation device, a drainage catheter left in place, or a monitoring lead positioned in the arm, forearm, wrist, or hand. External fixators are the most familiar example, used to stabilize complex fractures or soft-tissue injuries where internal repair is not yet feasible. The device supports healing or allows ongoing observation but does not itself perform the function of the tissue it sits within.
These procedures are typically staged: the device is inserted first, sometimes adjusted or exchanged later, and eventually removed once its purpose is fulfilled.
Anatomy & Axis Detail
Shoulder Region, Right
Insertion into the right shoulder region typically refers to placement of a device such as a nerve stimulator lead, drainage device, or infusion catheter into the soft tissue surrounding the shoulder joint, distinct from insertion of a device directly into the joint or into the humerus. This region includes the deltoid soft tissue envelope and the area overlying the rotator cuff, and devices placed here are often used for postoperative pain control catheters following rotator cuff repair or other shoulder surgery, or for peripheral nerve stimulator leads targeting the brachial plexus branches. Documentation should clarify that the device sits within the regional soft tissue rather than within the joint capsule or a specific muscle, since those would be coded to different, more specific body parts.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Radioactive Element
Radioactive Element identifies an implanted radioactive source, such as a brachytherapy seed, left in place to deliver localized therapeutic radiation over time. It is distinguished from other device categories by its therapeutic radioactive function rather than a structural, drainage, or monitoring purpose.
Coding & Documentation
Coders need the operative note to specify the device category, since the device value drives code selection more than the anatomic detail does. External fixation applied across a fracture site in the region, rather than to a single named bone, is the classic scenario for this body system. A frequent error is coding an external fixator here when it was actually applied to a specific bone that has its own body part value, or confusing insertion with the initial application of a fixation device coded under a different root operation in the bones system.
Commonly Confused With
This family is often confused with Insertion of a fixation device coded to a specific bone or joint body system - the deciding factor is whether the fixator spans the regional anatomy or attaches to one identifiable bone. It also differs from Change, which applies when a similar device is swapped out through the same site, and from Removal, which is used once the device's job is finished and it is taken out.