ICD-10-PCS Billable Code

0RHE03Z

Insertion Sternoclavicular Joint, Right to No Qualifier with Infusion Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemR Upper Joints
OperationH Insertion
Body PartE Sternoclavicular Joint, Right
Approach0 Open
Device3 Infusion Device
QualifierZ No Qualifier

Operation Definition

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Procedure Overview

Insertion procedures in the upper joints place a nonbiological device into or around a joint, such as a spacer, an internal fixation device used independently of a fusion or repair, or a joint-related monitoring device, without that device taking the place of any body part itself. The device supports, stabilizes, or monitors the joint rather than replacing joint tissue, which sets Insertion apart from procedures like Replacement or Fusion where hardware is used to help rebuild or immobilize a structure.

A common example is placing a temporary antibiotic spacer in a joint during a staged infection treatment, or inserting hardware to stabilize a joint as an isolated procedure separate from any other repair. These devices are typically intended to remain in the body for a period of treatment or, in some cases, permanently, and the procedure itself does not involve cutting out or repairing the underlying joint tissue.

Anatomy & Axis Detail

Sternoclavicular Joint, Right

The right sternoclavicular joint links the medial clavicle to the manubrium and first costal cartilage, functioning as the sole bony connection between the upper limb and the axial skeleton. Its disc and dense capsular ligaments make it a stable but shallow joint, susceptible to septic arthritis, particularly in intravenous drug users, and to instability from trauma. Insertion here typically involves placing an antibiotic-impregnated spacer, drug-delivery device, or diagnostic lead into the joint space without removing native tissue, often as a staged step in managing infection before definitive reconstruction. Given the joint's proximity to the great vessels and mediastinal structures immediately posterior to it, careful imaging and a controlled anterior approach are used, and documentation should reflect the right-sided location precisely.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Infusion Device

Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.

Coding & Documentation

Coders need documentation that clearly identifies the device inserted and confirms that no body part was excised, repaired, or replaced during the same encounter, since many operative notes describe hardware placement as part of a broader repair or fusion that would be coded differently. The approach, whether open, percutaneous, or percutaneous endoscopic, must be specified, and the device category (such as spacer or internal fixation device) determines the correct device value. A frequent mistake is coding routine fixation hardware placed during a fracture repair or fusion as a separate Insertion procedure, when it should instead be captured within the device qualifier of the primary root operation rather than coded again independently.

Commonly Confused With

ReplacementReplacement is distinguished from Insertion because Replacement substitutes all or part of a joint with a device that physically takes over that body part's function, while Insertion places a device that supports or monitors the joint without functionally replacing it.
FusionFusion often uses internal fixation hardware as well, but that hardware is captured through the Fusion device qualifier rather than coded separately as Insertion.
ExcisionWhen a spacer or device placement is one step within a staged procedure that also involves removing infected tissue, the tissue removal portion is coded separately using Excision or Extirpation, with Insertion reserved for the device placement itself.