ICD-10-PCS Billable Code

B837ZZZ

Magnetic Resonance Imaging (MRI) Eyes, Bilateral to None with None, None Approach

Procedural Specifications

Clinical Axis Detail Definition
SectionB Imaging
Body System8 Eye
Operation3 Magnetic Resonance Imaging (MRI)
Body Part7 Eyes, Bilateral
ApproachZ None
DeviceZ None
QualifierZ None

Operation Definition

Computer reformatted digital display of multiplanar images developed from the capture of radiofrequency signals emitted by nuclei in a body site excited within a magnetic field

Procedure Overview

Magnetic resonance imaging of the eye and surrounding orbit produces detailed cross-sectional pictures of the globe, optic nerve, extraocular muscles, and soft tissues without using radiation. A strong magnetic field and radio waves excite hydrogen nuclei in the tissue, and a computer reconstructs the returning signals into images that can be viewed in multiple planes. Because it distinguishes soft tissue types so well, it is often the preferred study for evaluating structures that plain films or CT cannot separate clearly.

Physicians order this imaging to investigate orbital tumors, suspected optic nerve inflammation or compression, vascular malformations, inflammatory conditions such as orbital pseudotumor, and to characterize masses found on prior exams. It is also used when a metallic foreign body has already been ruled out, since the magnet can move ferromagnetic material and cause serious injury. Contrast agents may be given to highlight areas of abnormal blood vessel activity or tumor enhancement.

Anatomy & Axis Detail

Eyes, Bilateral

Bilateral orbital MRI images both eyes and their surrounding structures together, which is valuable when a disease process is expected to be symmetric or when comparing the two sides helps establish a diagnosis, such as in bilateral optic neuritis associated with multiple sclerosis or neuromyelitis optica, or in symmetric thyroid-associated orbitopathy. The high soft-tissue resolution lets the radiologist assess both optic nerves along their full course as well as the extraocular muscles and orbital fat, distinguishing subtle asymmetries that guide whether one or both sides require treatment. Because MRI avoids radiation, it is well suited to conditions requiring serial follow-up in both eyes over time. A thorough screen for ferromagnetic foreign material is required before scanning, and findings for each eye should be reported individually within the single bilateral study.

Coding & Documentation

Coders assign this code when the documentation confirms MRI was performed specifically on the eye or orbit, with or without contrast, and the report should state the technique used and any contrast administration. A common assignment error is confusing orbit imaging with imaging of adjacent structures such as the brain or sinuses when the study actually extended into those regions, which changes the body system. Another frequent mistake is failing to distinguish between unenhanced, contrast-enhanced, and combined unenhanced/enhanced studies, since ICD-10-PCS imaging tables differentiate these approaches and the physician note or radiology order must clearly support the qualifier selected.

Commonly Confused With

This family is easily confused with CT of the orbit, which uses ionizing radiation and reconstructs images from x-ray attenuation rather than magnetic resonance signals; the distinguishing factor is the modality itself, documented plainly in the radiology report. It can also be mixed up with orbital ultrasonography, a real-time bedside technique that uses sound waves and is typically reserved for anterior segment or superficial evaluation rather than deep orbital detail. Reviewing the equipment and technique described in the report resolves the distinction.