0FL80CZ
Occlusion Cystic Duct to No Qualifier with Extraluminal Device, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | F Hepatobiliary System and Pancreas |
| Operation | L Occlusion |
| Body Part | 8 Cystic Duct |
| Approach | 0 Open |
| Device | C Extraluminal Device |
| Qualifier | Z No Qualifier |
Operation Definition
Completely closing an orifice or the lumen of a tubular body part
Procedure Overview
Occlusion procedures in this body system close off a duct, vessel, or opening within the liver, gallbladder, bile ducts, or pancreas so that fluid can no longer pass through it. This is most often performed on a bile duct or pancreatic duct that is leaking, diseased, or being deliberately sealed to redirect flow elsewhere, and less commonly on a blood vessel supplying these organs to stop bleeding or cut off circulation to a tumor.
Clinicians use this approach when a duct has been injured, is fistulizing to another structure, or needs to be sacrificed as part of a larger surgical plan, such as closing a stump left after partial removal of an organ. It may also be used to block blood flow into a tumor before resection, reducing bleeding risk during the main procedure.
The underlying idea is that the tubular structure remains anatomically in place but its lumen is deliberately shut, using clips, ligatures, embolic material, or a similar technique, rather than being cut out or repaired to restore normal function.
Anatomy & Axis Detail
Cystic Duct
The cystic duct connects the gallbladder to the common bile duct and is the structure most familiarly occluded during cholecystectomy, where it is clipped or ligated to prevent bile leakage and control the cystic artery pedicle before the gallbladder is separated from the liver bed. Occlusion of the cystic duct independent of gallbladder removal is less common but may be performed to manage a leak from a retained cystic duct stump or to close off a duct during a staged procedure. Its short length and variable insertion point into the common bile duct, sometimes running parallel to it for some distance, make correct identification essential, and operative documentation should be checked to ensure the closure was intentional and not simply a step within a broader cholecystectomy.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Extraluminal Device
Extraluminal Device describes a device positioned on the outside surface of a tubular or hollow body part rather than within its lumen, such as a vascular banding or external stabilization device. It is the structural counterpart to Intraluminal Device, distinguished by its external placement relative to the vessel or duct wall rather than sitting inside the passageway itself.
Coding & Documentation
Coders should look for explicit documentation that a duct or vessel was ligated, clipped, coiled, embolized, or otherwise closed off completely, and confirm which specific structure and approach was used, since embolization performed percutaneously through interventional radiology is coded differently in device and approach values than a duct tied off during open surgery. The device value must reflect whether an extraluminal device such as a clip or ligature, or an intraluminal device such as a coil, was left in place.
A frequent error is confusing partial narrowing or compression of a duct with true occlusion, when the intent and result must be complete closure of the lumen. Another common mistake is coding Occlusion when the vessel or duct was actually cut and its ends tied off as an incidental part of a different procedure, such as division during a resection, in which case the occlusion is not coded separately.