ICD-10-PCS Billable Code

06L24DZ

Occlusion Gastric Vein to No Qualifier with Intraluminal Device, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System6 Lower Veins
OperationL Occlusion
Body Part2 Gastric Vein
Approach4 Percutaneous Endoscopic
DeviceD Intraluminal Device
QualifierZ No Qualifier

Operation Definition

Completely closing an orifice or the lumen of a tubular body part

Procedure Overview

Occlusion procedures in the lower veins permanently close off a vessel so blood can no longer flow through it. This is most often used to treat varicose veins, where a diseased or refluxing segment of the great or small saphenous vein is sealed shut, redirecting blood into healthier veins nearby. It's also used to block off perforator veins that are feeding chronic leg ulcers or to close a vessel that's actively bleeding.

Techniques vary widely: some use heat from a laser or radiofrequency catheter to scar the vein wall shut from the inside, others inject a sclerosing chemical or medical adhesive, and some use mechanically placed clips, ligatures, or coils, including vena cava filters that occlude flow to prevent clots from traveling to the lungs.

Patients typically pursue this for cosmetic or symptomatic varicose vein relief, or as a more urgent measure to manage clotting risk or uncontrolled bleeding.

Anatomy & Axis Detail

Gastric Vein

Gastric veins drain the stomach wall and communicate directly with the esophageal venous plexus, making them a key pathway through which portal hypertension produces gastroesophageal varices. Occlusion of a gastric vein is performed to interrupt this route of collateral flow, most commonly during balloon-occluded retrograde transvenous obliteration or similar variceal management procedures aimed at controlling or preventing bleeding from gastric varices. Because these veins are small and variably arranged, with communication to splenic and renal venous drainage in some patients, occlusion often requires careful catheter positioning under fluoroscopic guidance to ensure the correct varix-feeding vessel is closed. Successful occlusion here can meaningfully reduce rebleeding risk in patients with cirrhosis-related portal hypertension who are poor candidates for more extensive shunt procedures.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Intraluminal Device

Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.

Coding & Documentation

The documentation needs to clearly establish that the vein's lumen was fully closed, not just narrowed or repaired, and coders must select the correct approach value based on whether the closure was done via an open incision, a percutaneous needle stick, or an endoscopic catheter, since energy-based ablation and chemical sclerotherapy are both captured as Occlusion despite using very different tools.

A frequent assignment error is confusing a vena cava filter placement, which is an Occlusion combined with a device value, with a simple ligation that requires no device code at all. Coders also sometimes miss that laser and radiofrequency ablation both map to Occlusion with a qualifier reflecting the specific method, rather than to Destruction, which is not used for this body system's ablation procedures.

Commonly Confused With

RestrictionOcclusion is frequently mixed up with Restriction, but Restriction only partially narrows a vessel's lumen rather than closing it completely, and the two root operations are not interchangeable even when the clinical intent looks similar.
ExcisionIt's also distinct from Excision or Extirpation, which remove diseased tissue or clot material rather than sealing the vessel, and from Repair, which is used when a vein wall defect is closed without the goal of stopping all flow through it.