ICD-10-PCS Billable Code

04L30CZ

Occlusion Hepatic Artery to No Qualifier with Extraluminal Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System4 Lower Arteries
OperationL Occlusion
Body Part3 Hepatic Artery
Approach0 Open
DeviceC Extraluminal Device
QualifierZ No Qualifier

Operation Definition

Completely closing an orifice or the lumen of a tubular body part

Procedure Overview

Occlusion procedures on the lower arteries deliberately seal off a vessel's opening or lumen so blood can no longer pass through it. This is done using techniques like embolization coils, particles, or glue delivered through a catheter, or by surgically tying off the artery, and it serves purposes ranging from stopping dangerous bleeding to cutting blood supply to a tumor or an abnormal vascular connection. Unlike most procedures aimed at restoring flow, this family intentionally blocks it.

Common reasons for occlusion include controlling a bleeding vessel after trauma or during surgery, shrinking uterine fibroids by blocking their blood supply, treating an aneurysm by closing off the feeding artery, or managing internal bleeding from the gastrointestinal or pelvic arteries. The approach can be catheter-based and minimally invasive or performed as part of an open surgical procedure.

Anatomy & Axis Detail

Hepatic Artery

The hepatic artery, arising from the celiac trunk, delivers a substantial share of the liver's oxygenated blood and is a frequent target for occlusion when treating hepatocellular carcinoma or metastatic liver tumors through embolization techniques, or when controlling traumatic hepatic bleeding. Its proper and common segments run close to the portal vein and bile duct within the hepatoduodenal ligament, so occlusion performed surgically requires careful identification of this anatomy to avoid injuring adjacent structures. Because the liver has a dual blood supply from both the hepatic artery and portal vein, temporary or even permanent occlusion of the arterial component is often tolerated, which is part of why this vessel is a preferred route for catheter-directed tumor therapy.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Extraluminal Device

Extraluminal Device describes a device positioned on the outside surface of a tubular or hollow body part rather than within its lumen, such as a vascular banding or external stabilization device. It is the structural counterpart to Intraluminal Device, distinguished by its external placement relative to the vessel or duct wall rather than sitting inside the passageway itself.

Coding & Documentation

Coders should look for clear language that the artery was closed off entirely - terms like embolization, coiling, ligation, or clipping - and confirm from the note that the intent and result was complete closure rather than partial narrowing. The specific artery occluded needs to match the correct body part value, which for pelvic and reproductive procedures like uterine fibroid embolization can involve multiple small branches. A frequent mistake is confusing partial narrowing intended to reduce but not eliminate flow with true occlusion, or missing that embolization material used therapeutically differs from diagnostic catheter placement, which would not be separately coded.

Commonly Confused With

RestrictionRestriction is the procedure most easily confused with Occlusion, since both narrow a vessel, but Restriction only partially reduces the diameter or flow while Occlusion eliminates it completely - the operative note's description of the intended endpoint is the deciding factor.
DestructionDestruction is another neighboring concept when tissue rather than a vessel lumen is being eliminated, and coders should check whether the artery itself was closed versus abnormal tissue fed by it being obliterated.