ICD-10-PCS Billable Code

07LH3DZ

Occlusion Lymphatic, Right Inguinal to No Qualifier with Intraluminal Device, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System7 Lymphatic and Hemic Systems
OperationL Occlusion
Body PartH Lymphatic, Right Inguinal
Approach3 Percutaneous
DeviceD Intraluminal Device
QualifierZ No Qualifier

Operation Definition

Completely closing an orifice or the lumen of a tubular body part

Procedure Overview

Occlusion procedures close off a lymphatic vessel or duct so that fluid can no longer pass through it, most notably ligation of the thoracic duct to control a chylous leak or chylothorax where lymphatic fluid is escaping into the chest. A surgeon ties off, clips, or otherwise seals the vessel, either through an open approach or thoracoscopically, redirecting or stopping the flow of lymph at that point.

This is a targeted response to a specific mechanical problem, a duct that's leaking or that needs to be interrupted, rather than a treatment aimed at disease within the node or organ itself. It's used when conservative measures like dietary changes or drainage haven't resolved persistent lymphatic leakage, often following thoracic or cardiac surgery, trauma, or in association with certain tumors.

Because the vessel is completely closed rather than partially narrowed or removed, the tissue beyond the occlusion loses its normal drainage pathway, which is why the procedure is typically reserved for cases where an alternate route for lymph flow exists or the leak itself poses the greater risk.

Anatomy & Axis Detail

Lymphatic, Right Inguinal

The right inguinal lymph nodes and vessels sit in the groin crease, receiving drainage from the right lower extremity, external genitalia, and lower abdominal wall before passing centrally toward the pelvic chain. Occlusion in this region is most often performed to control a postoperative lymphocele or persistent lymphatic leak following right inguinal lymph node dissection, hernia repair, or vascular access procedures at the femoral vessels, which run in close proximity. Because the inguinal region contains a dense cluster of nodes alongside the femoral artery, vein, and nerve, careful dissection is required to isolate the specific leaking channel without disturbing these adjacent structures. Right-sided laterality must be clearly documented, distinguishing this code from the left inguinal lymphatic group.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Intraluminal Device

Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.

Coding & Documentation

The note should specify the duct or lymphatic vessel occluded, most commonly the thoracic duct, and the technique used - ligation, clipping, or another method that completely closes the lumen - along with the clinical reason, typically a documented chylothorax or chyle leak. Confirming that the vessel is fully closed, not just narrowed or partially interrupted, supports Occlusion over another root operation.

Coders sometimes misassign a percutaneous lymphatic embolization procedure to the wrong root operation by not distinguishing embolic material placed to occlude the duct from a device left for another purpose, or by missing that thoracic duct ligation performed incidentally during a larger thoracic operation still needs its own separate code.

Commonly Confused With

Restriction is the operation most likely to be confused with Occlusion, since both narrow or block a passage, but Restriction only partially narrows the lumen while Occlusion closes it completely - a detail that has to come directly from the operative description of what was accomplished. Ligation for hemostasis during an unrelated procedure, where a small lymphatic is tied off incidentally to control oozing, generally isn't coded separately from the primary procedure, unlike a deliberate therapeutic duct ligation performed to treat a leak.