ICD-10-PCS Billable Code

07L30CZ

Occlusion Lymphatic, Right Upper Extremity to No Qualifier with Extraluminal Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System7 Lymphatic and Hemic Systems
OperationL Occlusion
Body Part3 Lymphatic, Right Upper Extremity
Approach0 Open
DeviceC Extraluminal Device
QualifierZ No Qualifier

Operation Definition

Completely closing an orifice or the lumen of a tubular body part

Procedure Overview

Occlusion procedures close off a lymphatic vessel or duct so that fluid can no longer pass through it, most notably ligation of the thoracic duct to control a chylous leak or chylothorax where lymphatic fluid is escaping into the chest. A surgeon ties off, clips, or otherwise seals the vessel, either through an open approach or thoracoscopically, redirecting or stopping the flow of lymph at that point.

This is a targeted response to a specific mechanical problem, a duct that's leaking or that needs to be interrupted, rather than a treatment aimed at disease within the node or organ itself. It's used when conservative measures like dietary changes or drainage haven't resolved persistent lymphatic leakage, often following thoracic or cardiac surgery, trauma, or in association with certain tumors.

Because the vessel is completely closed rather than partially narrowed or removed, the tissue beyond the occlusion loses its normal drainage pathway, which is why the procedure is typically reserved for cases where an alternate route for lymph flow exists or the leak itself poses the greater risk.

Anatomy & Axis Detail

Lymphatic, Right Upper Extremity

Occlusion of right upper extremity lymphatics closes lymphatic channels draining the right arm, a procedure occasionally performed to manage a localized lymphatic leak or malformation, though clinicians must weigh this against the risk of worsening lymphedema, since the upper limb depends on these vessels to return interstitial fluid to central circulation. This concern is especially relevant after axillary lymph node dissection for breast cancer, where residual lymphatic pathways are already compromised. When occlusion is undertaken, it typically targets a specific leaking or malformed channel identified through lymphangiography or direct visualization rather than the entire regional network, in an effort to control the immediate problem while preserving as much residual drainage capacity as possible.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Extraluminal Device

Extraluminal Device describes a device positioned on the outside surface of a tubular or hollow body part rather than within its lumen, such as a vascular banding or external stabilization device. It is the structural counterpart to Intraluminal Device, distinguished by its external placement relative to the vessel or duct wall rather than sitting inside the passageway itself.

Coding & Documentation

The note should specify the duct or lymphatic vessel occluded, most commonly the thoracic duct, and the technique used - ligation, clipping, or another method that completely closes the lumen - along with the clinical reason, typically a documented chylothorax or chyle leak. Confirming that the vessel is fully closed, not just narrowed or partially interrupted, supports Occlusion over another root operation.

Coders sometimes misassign a percutaneous lymphatic embolization procedure to the wrong root operation by not distinguishing embolic material placed to occlude the duct from a device left for another purpose, or by missing that thoracic duct ligation performed incidentally during a larger thoracic operation still needs its own separate code.

Commonly Confused With

Restriction is the operation most likely to be confused with Occlusion, since both narrow or block a passage, but Restriction only partially narrows the lumen while Occlusion closes it completely - a detail that has to come directly from the operative description of what was accomplished. Ligation for hemostasis during an unrelated procedure, where a small lymphatic is tied off incidentally to control oozing, generally isn't coded separately from the primary procedure, unlike a deliberate therapeutic duct ligation performed to treat a leak.