ICD-10-PCS Billable Code

BU021ZZ

Plain Radiography Fallopian Tubes, Bilateral to None with None, Low Osmolar Approach

Procedural Specifications

Clinical Axis Detail Definition
SectionB Imaging
Body SystemU Female Reproductive System
Operation0 Plain Radiography
Body Part2 Fallopian Tubes, Bilateral
Approach1 Low Osmolar
DeviceZ None
QualifierZ None

Operation Definition

Planar display of an image developed from the capture of external ionizing radiation on photographic or photoconductive plate

Procedure Overview

Plain radiography of the female reproductive system uses a brief burst of external X-rays captured on a plate to create a flat, two-dimensional image of pelvic structures. It has largely been supplanted by ultrasound and MRI for evaluating the uterus and ovaries directly, but a plain film is still used in specific situations, such as locating a retained intrauterine device, assessing pelvic bony anatomy alongside soft tissue, or as part of a hysterosalpingogram sequence.

The test is fast and produces a single static image rather than a moving or layered view, so it works best for questions with a clear anatomic answer - is a device present, has an object migrated, are there calcifications - rather than for characterizing soft-tissue masses. Because it uses ionizing radiation, it is avoided during pregnancy unless clinically necessary.

Anatomy & Axis Detail

Fallopian Tubes, Bilateral

Coding both fallopian tubes together applies when a single plain film is obtained to survey the entire adnexal region rather than one side in isolation, as in a preoperative check for bilateral sterilization clips or a search for calcified tubal pathology such as old salpingitis. Because plain radiography lacks the contrast resolution to trace the tubes' course, a bilateral study is typically a scout or control image taken immediately before or after a contrast procedure, confirming clip placement or ruling out retained hardware on both sides simultaneously. The bilateral code reflects that the anatomic field of view, not the clinical question, spans both tubes at once, and it should not be confused with a fluoroscopic hysterosalpingogram, which actually assesses patency of each tube separately.

Contrast: Low Osmolar

Low Osmolar denotes use of a low-osmolar iodinated contrast agent during an imaging study, the class most commonly used in modern radiographic and CT imaging because it better approximates the osmolality of blood and carries a lower risk of reaction than High Osmolar media. This value distinguishes studies performed with this now-standard contrast type from those using older high-osmolar agents or no contrast at all.

Coding & Documentation

Coders assign this family based on documentation that a static X-ray image, not a real-time or contrast-enhanced fluoroscopic series, was obtained, and that the field of view included female reproductive structures specifically. A common error is coding a hysterosalpingogram here when the procedure actually involved continuous fluoroscopic contrast imaging, which belongs in the fluoroscopy family instead. The report should also specify whether contrast material was used, since plain radiography by definition does not include contrast administration.

Commonly Confused With

The closest point of confusion is fluoroscopy of the female reproductive system, particularly hysterosalpingography, which looks similar in intent (imaging the uterus and tubes) but uses continuous real-time X-ray with contrast rather than a single static exposure. Ultrasonography and MRI of the same body system are also often ordered for overlapping indications but rely on sound waves or magnetic fields instead of ionizing radiation, and typically offer superior soft-tissue detail.