ICD-10-PCS Billable Code

C710YZZ

Planar Nuclear Medicine Imaging Bone Marrow to None with None, Other Radionuclide Approach

Procedural Specifications

Clinical Axis Detail Definition
SectionC Nuclear Medicine
Body System7 Lymphatic and Hematologic System
Operation1 Planar Nuclear Medicine Imaging
Body Part0 Bone Marrow
ApproachY Other Radionuclide
DeviceZ None
QualifierZ None

Operation Definition

Introduction of radioactive materials into the body for single plane display of images developed from the capture of radioactive emissions

Procedure Overview

Planar nuclear medicine imaging of the lymphatic and hematologic system covers single-plane scans that track how a radioactive tracer moves through lymph channels and nodes, or how it distributes through components of the blood. The best-known example is lymphoscintigraphy, in which a small dose of tracer is injected near a tumor site or in tissue and a gamma camera follows its path as it drains into nearby lymph nodes.

This type of imaging is used heavily in cancer surgery planning, particularly for breast cancer and melanoma, to identify the sentinel lymph node - the first node a tumor would drain to - so a surgeon can remove and biopsy that specific node rather than a wider group of nodes. It is also used to evaluate lymphedema, a condition where fluid builds up because lymph vessels are blocked or not draining properly, by showing where the flow of tracer slows or stops.

Anatomy & Axis Detail

Bone Marrow

Bone marrow occupies the medullary cavities of the skeleton and is the site of hematopoiesis, and scintigraphic imaging of it uses a radiotracer that localizes to functioning marrow to map the distribution of active blood-forming tissue throughout the body. This is useful for evaluating conditions where normal marrow is displaced or replaced, such as myelofibrosis, marrow infarction in sickle cell disease, or expansion of marrow activity in response to chronic anemia, and can reveal extension of hematopoietic tissue into areas that are normally fatty and inactive in adults. Because marrow activity is diffuse rather than confined to a single organ, the resulting images characterize a pattern across the axial and proximal appendicular skeleton rather than a discrete structure, distinguishing this study from imaging of a solid organ.

Radionuclide: Other Radionuclide

Other Radionuclide is used when a nuclear medicine study employs a radioactive tracer that does not correspond to one of the specifically named isotope values in this axis, such as an uncommon or newer radiopharmaceutical. It functions as a catch-all so the procedure can still be coded precisely by section and root operation even when the exact tracer lacks its own dedicated code value.

Coding & Documentation

The clinical note should specify the injection site, the substance traced, and confirm that the images acquired were flat, single-plane pictures. Sentinel node mapping studies are frequently paired with a same-day surgical excision, and coders need to capture the imaging and the surgical removal as separate procedures even though they are clinically linked. A common mistake is failing to distinguish a lymphatic mapping study from a general blood-pool or marrow imaging study, since both fall under the same body system in the classification but represent very different clinical targets.

Commonly Confused With

This family is frequently confused with Tomographic Nuclear Medicine Imaging of the same body system, which produces three-dimensional images rather than flat ones and is often used for spleen or bone marrow studies rather than lymph node mapping; the report's description of the acquisition technique settles which applies. It is also sometimes confused with sentinel node biopsy itself, which is a separate excision procedure coded outside of Nuclear Medicine even when performed immediately after the imaging study that located the node.