ICD-10-PCS Billable Code

C819YZZ

Planar Nuclear Medicine Imaging Lacrimal Ducts, Bilateral to None with None, Other Radionuclide Approach

Procedural Specifications

Clinical Axis Detail Definition
SectionC Nuclear Medicine
Body System8 Eye
Operation1 Planar Nuclear Medicine Imaging
Body Part9 Lacrimal Ducts, Bilateral
ApproachY Other Radionuclide
DeviceZ None
QualifierZ None

Operation Definition

Introduction of radioactive materials into the body for single plane display of images developed from the capture of radioactive emissions

Procedure Overview

This family covers planar nuclear medicine imaging of the eye, a diagnostic study in which a radioactive tracer is introduced into the body and a gamma camera captures a single flat image of the emissions concentrating in ocular tissue. It is used far less often than imaging of other organ systems, typically reserved for evaluating suspected ocular tumors, orbital masses, or unusual inflammatory conditions when other imaging methods such as ultrasound or MRI have left questions unanswered. The tracer distributes according to blood flow and tissue metabolism, and areas of abnormal uptake can point toward active disease processes within or around the eye.

Anatomy & Axis Detail

Lacrimal Ducts, Bilateral

The lacrimal ducts are the paired drainage channels, canaliculi, sac, and nasolacrimal duct, that carry tears from the eye into the nasal cavity. Imaging both sides at once is standard because obstruction is often unilateral and the contralateral duct serves as a built-in comparison for transit time. A radiotracer is instilled onto the ocular surface, typically as an eye drop, and its passage through the drainage system is followed on planar images over several minutes, a study often called a dacryoscintigram. Delayed or absent clearance points to a blockage, while its level along the duct can suggest whether the problem lies in the canaliculi, the sac, or the distal nasolacrimal segment, helping guide whether probing, dilation, or surgery is warranted.

Radionuclide: Other Radionuclide

Other Radionuclide is used when a nuclear medicine study employs a radioactive tracer that does not correspond to one of the specifically named isotope values in this axis, such as an uncommon or newer radiopharmaceutical. It functions as a catch-all so the procedure can still be coded precisely by section and root operation even when the exact tracer lacks its own dedicated code value.

Coding & Documentation

Documentation supporting this code should show that a radioactive tracer was administered and that a single-plane gamma camera image of the orbit or eye was obtained and interpreted by the nuclear medicine or radiology physician. Coders need to confirm the target body part is genuinely the eye rather than a broader head and neck study that happens to include the orbit incidentally, since imaging of adjacent structures like the sinuses or brain falls under different body system values. A common assignment error is defaulting to a more frequently used body system code out of habit rather than verifying the specific anatomic target named in the report, or overlooking that a same-day CT or MRI of the orbit is a separate, non-nuclear-medicine procedure that should be coded independently.

Commonly Confused With

This procedure is sometimes confused with computed tomography or magnetic resonance imaging of the eye and orbit, which use different physical principles and belong to entirely different sections of the coding system rather than nuclear medicine. Within nuclear medicine itself, it can be confused with SPECT or PET imaging of the head that happens to capture the orbital region, but those use tomographic, multi-plane reconstruction techniques rather than the single flat image that defines planar imaging. The distinguishing factor is both the imaging modality, planar versus cross-sectional, and the specifically documented target of the eye rather than surrounding structures.

Procedural Guidance & FAQs

Coding Accuracy

Is C819YZZ a billable procedure?

Yes, C819YZZ is a complete, 7-character procedural specification that is acceptable for hospital claim reimbursement.

Technical Axis

What approach is used for C819YZZ?

This procedure utilizes the Other Radionuclide approach, mapping to the 5th character in the PCS axis.

Metadata Tags

planar bilateral nuclear lacrimal imaging medicine radionuclide