0RPG4KZ
Removal Acromioclavicular Joint, Right to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | R Upper Joints |
| Operation | P Removal |
| Body Part | G Acromioclavicular Joint, Right |
| Approach | 4 Percutaneous Endoscopic |
| Device | K Nonautologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures on the upper joints take out a device that was previously placed in the joint during an earlier operation, without putting anything else in its place. This covers situations like extracting hardware such as pins, screws, or wires used for a prior fracture repair once the bone has healed, removing an infected or loosened joint spacer, or taking out sutures, anchors, or other fixation devices that are no longer needed or are causing problems.
These procedures are performed when a device has served its purpose, has failed, is causing pain or irritation, or has become infected and needs to come out before any further treatment can proceed.
Anatomy & Axis Detail
Acromioclavicular Joint, Right
The right acromioclavicular joint is a small, superficial synovial joint linking the acromion of the scapula to the distal clavicle, commonly stabilized surgically after separation injuries with hardware like hook plates, screws, or synthetic ligament reconstruction devices. Removal describes taking out such a previously implanted device once healing is sufficient, without inserting a new one in its place. Because this joint is subcutaneous and mobile with shoulder motion, retained hardware frequently causes local irritation, prominence, or impingement against the deltoid, which is a common indication for extraction. The procedure is usually straightforward compared to deeper joint work, but documentation should specify the device removed and confirm no concurrent repair or reconstruction was performed during the same operative encounter.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Nonautologous Tissue Substitute
Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.
Coding & Documentation
Coding this family requires documentation that a device is being taken out and that nothing is being put in its place during the same operative episode - if a new device is implanted after removal, the procedure is coded instead as Replacement or Revision depending on what happened to the joint itself. The device type and its original purpose should be clear in the note to support the correct device value.
A common error is coding Removal for hardware taken out during a revision arthroplasty, when the removal of an old component and insertion of a new one in the same joint at the same session should instead be captured as a single Replacement procedure. Coders also sometimes overlook that removal of a device from a joint accompanied by repair of joint damage caused by that device requires an additional Repair or Revision code for the corrected tissue.