0RPG38Z
Removal Acromioclavicular Joint, Right to No Qualifier with Spacer, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | R Upper Joints |
| Operation | P Removal |
| Body Part | G Acromioclavicular Joint, Right |
| Approach | 3 Percutaneous |
| Device | 8 Spacer |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures on the upper joints take out a device that was previously placed in the joint during an earlier operation, without putting anything else in its place. This covers situations like extracting hardware such as pins, screws, or wires used for a prior fracture repair once the bone has healed, removing an infected or loosened joint spacer, or taking out sutures, anchors, or other fixation devices that are no longer needed or are causing problems.
These procedures are performed when a device has served its purpose, has failed, is causing pain or irritation, or has become infected and needs to come out before any further treatment can proceed.
Anatomy & Axis Detail
Acromioclavicular Joint, Right
The right acromioclavicular joint is a small, superficial synovial joint linking the acromion of the scapula to the distal clavicle, commonly stabilized surgically after separation injuries with hardware like hook plates, screws, or synthetic ligament reconstruction devices. Removal describes taking out such a previously implanted device once healing is sufficient, without inserting a new one in its place. Because this joint is subcutaneous and mobile with shoulder motion, retained hardware frequently causes local irritation, prominence, or impingement against the deltoid, which is a common indication for extraction. The procedure is usually straightforward compared to deeper joint work, but documentation should specify the device removed and confirm no concurrent repair or reconstruction was performed during the same operative encounter.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Spacer
In Medical and Surgical procedures, a Spacer is a temporary, non-articulating device left in a joint or space after a component is removed, most often an antibiotic-impregnated cement block placed during a staged joint revision to control infection while preserving space and alignment. It is not intended to move like a real joint. It differs from an Articulating Spacer, which is shaped to permit some motion during the interim period, and from a permanent Synthetic Substitute.
Coding & Documentation
Coding this family requires documentation that a device is being taken out and that nothing is being put in its place during the same operative episode - if a new device is implanted after removal, the procedure is coded instead as Replacement or Revision depending on what happened to the joint itself. The device type and its original purpose should be clear in the note to support the correct device value.
A common error is coding Removal for hardware taken out during a revision arthroplasty, when the removal of an old component and insertion of a new one in the same joint at the same session should instead be captured as a single Replacement procedure. Coders also sometimes overlook that removal of a device from a joint accompanied by repair of joint damage caused by that device requires an additional Repair or Revision code for the corrected tissue.