0HPT3KZ
Removal Breast, Right to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | H Skin and Breast |
| Operation | P Removal |
| Body Part | T Breast, Right |
| Approach | 3 Percutaneous |
| Device | K Nonautologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
This family covers taking out a device that was previously placed in the skin or breast, without putting in a replacement. Common examples include removing a tissue expander after breast reconstruction is complete, taking out a wound vacuum-assisted closure device, removing a subcutaneous port or pump, or extracting sutures, staples, or drains that were left in place from an earlier procedure.
Removal is performed once the device has served its purpose, whether that means a temporary expander has stretched the skin enough for a permanent implant, an infection has resolved and hardware is no longer needed, or a wound has healed to the point that ongoing negative pressure therapy is unnecessary. In some cases the device is removed because it is malfunctioning, causing pain, or has become infected and must come out before treatment can continue.
The procedure itself can be as simple as an office visit to withdraw a drain, or it can require a return trip to the operating room to surgically extract a deeply seated expander or reservoir.
Anatomy & Axis Detail
Breast, Right
Removal from the right breast refers to extracting a previously placed device, such as a surgical drain, tissue expander, breast implant, or marker clip, rather than excising native breast tissue. Breast implants and expanders are commonly removed due to capsular contracture, rupture, infection, or patient preference for explantation, and the surrounding fibrous capsule that forms around such devices is a key anatomic consideration during extraction. Drains placed after mastectomy or reconstructive surgery are also removed once output decreases sufficiently. Because the right breast may have a distinct implant type, pocket location, or surgical history from the left, laterality and device specifics should be clearly documented to select the correct code.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Nonautologous Tissue Substitute
Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.
Coding & Documentation
Coding depends on clear documentation of what specific device was removed and where it was located, since skin and breast each have distinct body part values and a nonspecific note such as 'device removed' is not enough to assign a precise code. The operative report should confirm no new device was placed at the same encounter; if one was, the encounter belongs under Replacement instead.
A common mistake is coding Removal when the physician actually exchanged one device for another in the same session, which should be captured as Replacement rather than a standalone removal. Coders also sometimes overlook that removing sutures or superficial dressings that are not classified as procedural devices should not be coded at all, since ICD-10-PCS only captures removal of devices meeting the system's device definition. Confirming whether the device removal was performed via open incision or percutaneously is also essential for the approach character.