ICD-10-PCS Billable Code

0HPT8KZ

Removal Breast, Right to No Qualifier with Nonautologous Tissue Substitute, Via Natural or Artificial Opening Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemH Skin and Breast
OperationP Removal
Body PartT Breast, Right
Approach8 Via Natural or Artificial Opening Endoscopic
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

This family covers taking out a device that was previously placed in the skin or breast, without putting in a replacement. Common examples include removing a tissue expander after breast reconstruction is complete, taking out a wound vacuum-assisted closure device, removing a subcutaneous port or pump, or extracting sutures, staples, or drains that were left in place from an earlier procedure.

Removal is performed once the device has served its purpose, whether that means a temporary expander has stretched the skin enough for a permanent implant, an infection has resolved and hardware is no longer needed, or a wound has healed to the point that ongoing negative pressure therapy is unnecessary. In some cases the device is removed because it is malfunctioning, causing pain, or has become infected and must come out before treatment can continue.

The procedure itself can be as simple as an office visit to withdraw a drain, or it can require a return trip to the operating room to surgically extract a deeply seated expander or reservoir.

Anatomy & Axis Detail

Breast, Right

Removal from the right breast refers to extracting a previously placed device, such as a surgical drain, tissue expander, breast implant, or marker clip, rather than excising native breast tissue. Breast implants and expanders are commonly removed due to capsular contracture, rupture, infection, or patient preference for explantation, and the surrounding fibrous capsule that forms around such devices is a key anatomic consideration during extraction. Drains placed after mastectomy or reconstructive surgery are also removed once output decreases sufficiently. Because the right breast may have a distinct implant type, pocket location, or surgical history from the left, laterality and device specifics should be clearly documented to select the correct code.

Approach: Via Natural or Artificial Opening Endoscopic

Via Natural or Artificial Opening Endoscopic describes instrumentation introduced through a natural orifice or a surgically created opening while using an endoscope for visualization, as in a routine colonoscopy performed through the anus. It differs from the plain Via Natural or Artificial Opening value by the added scope, and from Percutaneous Endoscopic by using an existing passage rather than a new skin puncture.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Coding depends on clear documentation of what specific device was removed and where it was located, since skin and breast each have distinct body part values and a nonspecific note such as 'device removed' is not enough to assign a precise code. The operative report should confirm no new device was placed at the same encounter; if one was, the encounter belongs under Replacement instead.

A common mistake is coding Removal when the physician actually exchanged one device for another in the same session, which should be captured as Replacement rather than a standalone removal. Coders also sometimes overlook that removing sutures or superficial dressings that are not classified as procedural devices should not be coded at all, since ICD-10-PCS only captures removal of devices meeting the system's device definition. Confirming whether the device removal was performed via open incision or percutaneously is also essential for the approach character.

Commonly Confused With

ReplacementRemoval is often confused with Replacement, which applies when an old device is taken out and a new one put in during the same operative episode; if only extraction occurs with no new device, it is Removal alone.
RevisionIt also overlaps conceptually with Revision, used when an existing device is being corrected or adjusted rather than fully taken out, such as repositioning a malfunctioning expander port.
ExtirpationExtirpation is a separate consideration when what is being taken out is not a device but solid matter like a foreign body or necrotic material embedded in the skin.