0RP13JZ
Removal Cervical Vertebral Joint to No Qualifier with Synthetic Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | R Upper Joints |
| Operation | P Removal |
| Body Part | 1 Cervical Vertebral Joint |
| Approach | 3 Percutaneous |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures on the upper joints take out a device that was previously placed in the joint during an earlier operation, without putting anything else in its place. This covers situations like extracting hardware such as pins, screws, or wires used for a prior fracture repair once the bone has healed, removing an infected or loosened joint spacer, or taking out sutures, anchors, or other fixation devices that are no longer needed or are causing problems.
These procedures are performed when a device has served its purpose, has failed, is causing pain or irritation, or has become infected and needs to come out before any further treatment can proceed.
Anatomy & Axis Detail
Cervical Vertebral Joint
A cervical vertebral joint refers to the facet articulations connecting adjacent cervical vertebrae, small paired joints that guide neck rotation and lateral bending while sharing load with the vertebral bodies and discs. Devices such as facet screws, interspinous spacers, or components of a posterior fixation construct may be placed at these joints to stabilize a segment affected by degeneration, instability, or prior fracture, and removal is the appropriate root operation when that hardware is extracted without substituting new material. Indications include hardware failure, painful prominence, infection, or confirmed fusion that no longer requires supplemental fixation. Because the cervical spine has multiple mobile segments in close proximity, the operative report should specify the vertebral level so the correct joint is captured.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
Coding this family requires documentation that a device is being taken out and that nothing is being put in its place during the same operative episode - if a new device is implanted after removal, the procedure is coded instead as Replacement or Revision depending on what happened to the joint itself. The device type and its original purpose should be clear in the note to support the correct device value.
A common error is coding Removal for hardware taken out during a revision arthroplasty, when the removal of an old component and insertion of a new one in the same joint at the same session should instead be captured as a single Replacement procedure. Coders also sometimes overlook that removal of a device from a joint accompanied by repair of joint damage caused by that device requires an additional Repair or Revision code for the corrected tissue.