ICD-10-PCS Billable Code

07PLXDZ

Removal Cisterna Chyli to No Qualifier with Intraluminal Device, External Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System7 Lymphatic and Hemic Systems
OperationP Removal
Body PartL Cisterna Chyli
ApproachX External
DeviceD Intraluminal Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

This family covers taking out a device that was previously placed in a lymphatic or hemic structure, such as a drain left in the splenic bed after surgery, a catheter used to manage a lymphatic leak, or a mesh or other implant associated with the spleen or thymus. The device itself is being removed; no tissue is being cut away or repaired in the process. These procedures are typically staged after an earlier operation, once the device has served its purpose - controlling drainage, supporting healing, or monitoring a surgical site.

For patients, this is usually a straightforward, low-risk step in recovery rather than a major operation, though it is still coded as a distinct procedure because it involves entering the body to retrieve the device.

Anatomy & Axis Detail

Cisterna Chyli

The cisterna chyli, the dilated lymphatic reservoir at the origin of the thoracic duct near the upper lumbar spine, may require removal when it is the site of a cyst, lymphatic malformation, or localized damage that cannot be repaired. Because it collects chyle from the lower extremities, pelvis, and abdominal viscera before that fluid ascends into the thoracic duct, excising any portion carries a real risk of disrupting lymphatic drainage and precipitating chylous ascites or leakage into the retroperitoneum. Its deep location adjacent to the aorta and vertebral bodies makes surgical access difficult, so removal is typically limited and deliberate rather than routine. Documentation should distinguish whether the excision was partial, reflecting the structure's small size and critical drainage role.

Approach: External

External approach applies to procedures performed directly on the skin or mucous membrane, or on an accessible body surface, without any instrumentation passing through a puncture or orifice. It covers things like manual reduction of a fracture or excision of a skin lesion. It differs from Via Natural or Artificial Opening in that no internal passage is entered at all, only the exposed surface.

Device: Intraluminal Device

Intraluminal Device denotes a single device, such as a stent or occlusion device, positioned within the lumen of a tubular body part like a vessel, duct, or airway to maintain patency or occlude flow. It carries no drug coating or radioactivity, distinguishing it from the drug-eluting, radioactive, and bioactive intraluminal device values, and from Extraluminal Device, which sits outside rather than inside the lumen.

Coding & Documentation

Coders need documentation identifying the specific device removed and confirming that removal is the entire action - if the surgeon also repairs tissue, replaces the device, or performs any other procedure during the same encounter, additional codes are needed alongside or instead of Removal. A frequent error is coding Removal when a device is actually being exchanged for a new one in the same body part; ICD-10-PCS handles a straight swap differently than a removal followed by a separate insertion. Another pitfall is confusing removal of a device from the lymphatic system with removal of a device from an adjacent structure (such as a vascular access line running near lymph nodes) - the device must be recorded against the lymphatic or hemic body part it was actually seated in.

Commonly Confused With

ExtractionRemoval is frequently mixed up with Extraction, which involves pulling out matter (like fluid or a foreign body) rather than a placed device, and with Revision, which adjusts or corrects a device left in place rather than taking it out entirely.
InsertionWhen a device is both removed and a new one placed in the same session, coders sometimes miss that a separate Insertion code is also required.