ICD-10-PCS Billable Code

0GPS30Z

Removal Endocrine Gland to No Qualifier with Drainage Device, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemG Endocrine System
OperationP Removal
Body PartS Endocrine Gland
Approach3 Percutaneous
Device0 Drainage Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal in this family covers taking out a device that was previously placed in or on an endocrine structure - for example a drain left after adrenal or thyroid surgery, a radioactive seed or marker placed near a gland, or a monitoring lead. It applies specifically to hardware and implanted materials, not to the glandular tissue itself.

Patients encounter this procedure when a temporary device has served its purpose and needs to come out, when a device has failed or become infected, or when a permanent device is being planned for replacement. Because endocrine glands are usually not fitted with long-term mechanical implants the way joints or hearts are, Removal in this body system is generally tied to short-term post-surgical devices or localization aids used during treatment.

Anatomy & Axis Detail

Endocrine Gland

This body part value applies to removal of endocrine gland tissue that does not correspond to one of the specifically named glands classified elsewhere in the system, such as certain paraganglia or other diffuse neuroendocrine tissue collections. Because endocrine tissue can be found in atypical or ectopic locations throughout the body, this generic value accommodates procedures where the excised structure is clearly glandular and hormonally active but does not fit a more specific anatomic code. The clinical indication typically involves a functioning or suspicious mass causing hormone excess or raising concern for malignancy, and the surgeon's approach depends heavily on the tissue's location and surrounding structures. Precise operative documentation identifying the tissue as endocrine in nature, along with its general anatomic site, helps ensure this catch-all value is applied appropriately rather than as a default for incomplete documentation.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Drainage Device

Drainage Device denotes a device such as a tube or catheter left in place to remove fluid, blood, or air from a body part or cavity following a procedure. It is distinguished from Monitoring Device, which senses and records physiologic data rather than evacuating substances from the body.

Coding & Documentation

A coder needs documentation identifying the specific device being taken out and confirming that no new device is being put in during the same operative step - if a device is removed and immediately replaced with a new one, Removal is coded together with an additional Insertion, Replacement, or the combined-value convention specified in the PCS tables. Notes should state the type of device and its original placement.

A common error is coding Removal when a device is actually being adjusted or repositioned rather than taken out entirely, which instead falls under Revision; another is failing to code the separate Insertion when a device is swapped rather than simply removed.

Commonly Confused With

RevisionRemoval is easily confused with Revision, which corrects or adjusts a malfunctioning device left in place rather than taking it out.
ExtirpationIt is also distinct from Extirpation, which removes solid matter such as a calcification or clot from a body part rather than a previously placed device.