ICD-10-PCS Billable Code

0VPM73Z

Removal Epididymis and Spermatic Cord to No Qualifier with Infusion Device, Via Natural or Artificial Opening Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemV Male Reproductive System
OperationP Removal
Body PartM Epididymis and Spermatic Cord
Approach7 Via Natural or Artificial Opening
Device3 Infusion Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures in this family involve taking out a device that was previously placed in a structure of the male reproductive system, such as a penile prosthesis, testicular prosthesis, or a drain, rather than treating native tissue. These are performed when a device has served its purpose, malfunctioned, become infected, or needs to be exchanged for a different device.

Patients encounter these procedures most often after a prior implant surgery, such as removal of a penile implant due to mechanical failure, erosion, or infection, or removal of a testicular prosthesis that was placed after orchiectomy. Depending on the reason for removal, a new device may or may not be placed during the same operative session, which affects how the encounter is coded overall.

Anatomy & Axis Detail

Epididymis and Spermatic Cord

For the epididymis and spermatic cord, Removal denotes extraction of a previously inserted device, such as a vasectomy occlusion clip, spring, or valve used for reversible contraception, or hardware left from a prior reconstructive procedure. The epididymis is the coiled duct atop the testis where sperm mature and are stored, while the spermatic cord bundles the vas deferens, vessels, and nerves as they course from the scrotum through the inguinal canal; devices here are typically small and situated close to delicate, easily disrupted structures. Removal may be pursued to restore fertility after a clip-based sterilization procedure, to address device migration or discomfort, or in preparation for a different intervention. Because the cord and epididymis are intimately associated with the testicular blood supply, careful dissection is needed to avoid compromising testicular viability, and coders should confirm from the operative note which specific device and anatomic component were involved.

Approach: Via Natural or Artificial Opening

Via Natural or Artificial Opening means the instrument reaches the target site by passing through an existing body orifice, such as the mouth or urethra, or a surgically created opening like a stoma, without additional incision or scope guidance. It is distinguished from the Endoscopic variant by the absence of a visualizing scope, and from External by actually traversing into the body through that opening.

Device: Infusion Device

Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.

Coding & Documentation

A Removal code is assigned only when a device is being taken out and documentation confirms no new device is being put in through the same procedure; if a device is removed and immediately replaced, coders instead consider whether Revision or a Removal-plus-Insertion combination better reflects what was documented. The operative note should name the specific device removed, such as inflatable penile prosthesis components or a testicular implant, and confirm complete extraction.

A common mistake is coding Removal when the physician actually performed a Revision, which corrects or adjusts a malfunctioning device without full removal and replacement, or when a device is removed and a new one is placed in the same operative episode, which requires reporting both Removal and Insertion rather than Removal alone. Coders should also verify the body part reflects where the device was located rather than the device type itself.

Commonly Confused With

RevisionRemoval is frequently confused with Revision, since both address problems with an existing device, but Revision corrects, adjusts, or partially replaces components in place while Removal takes the device out entirely.
InsertionIt is also distinguished from Insertion, which places a new device without removing an old one, and situations involving both an old device coming out and a new one going in require separate Removal and Insertion codes rather than a single combined code.