ICD-10-PCS Billable Code

0QP834Z

Removal Femoral Shaft, Right to No Qualifier with Internal Fixation Device, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemQ Lower Bones
OperationP Removal
Body Part8 Femoral Shaft, Right
Approach3 Percutaneous
Device4 Internal Fixation Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.

Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.

Anatomy & Axis Detail

Femoral Shaft, Right

The right femoral shaft is the long cylindrical midsection of the thighbone that typically houses an intramedullary rod or plate placed to stabilize a diaphyseal fracture. Removal at this level refers to taking out that hardware, most often after the fracture has fully healed and the rod or plate is no longer needed, or earlier if it causes thigh discomfort, restricts range of motion, or becomes infected. Because the femoral shaft is subject to substantial axial and torsional loading, extraction technique must account for bone remodeling around the implant and the risk of iatrogenic fracture during removal. Documentation should indicate laterality and the specific hardware extracted, and should be distinguished from any sequestrectomy or bone resection performed concurrently, which falls under a separate root operation.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Internal Fixation Device

Internal fixation device is the general value for hardware such as plates, screws, or rods placed within the body to stabilize bone or joint, used when a more specific configuration is not indicated. It stands in contrast to the named subtypes - Rigid Plate, Intramedullary, Sustained Compression, and Intramedullary Limb Lengthening - which specify how the hardware achieves stabilization.

Coding & Documentation

Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.

Commonly Confused With

RevisionRevision is the most common point of confusion, since both involve existing hardware; Revision applies when a malfunctioning or displaced device is corrected or adjusted in place rather than taken out entirely.
ChangeChange is distinct because it captures removing a device and inserting a similar one through the same access site in one continuous procedure, most often for external fixation pins, rather than a permanent extraction.
ExtirpationExtirpation is unrelated in intent but sometimes confused when hardware fragments or broken screw pieces are retrieved rather than an intact device.