ICD-10-PCS Billable Code

0QPJ47Z

Removal Fibula, Right to No Qualifier with Autologous Tissue Substitute, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemQ Lower Bones
OperationP Removal
Body PartJ Fibula, Right
Approach4 Percutaneous Endoscopic
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.

Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.

Anatomy & Axis Detail

Fibula, Right

The right fibula is a slender, non-weight-bearing bone whose main surgical relevance lies in ankle fracture fixation and as a harvest site for vascularized bone grafts, and Removal here refers to extracting hardware such as plates, screws, or syndesmotic fixation devices placed across the distal fibula and ankle mortise. Syndesmotic screws in particular are often intentionally removed after a defined healing interval to restore normal physiologic motion between the tibia and fibula, since leaving rigid fixation in place can eventually cause screw breakage or restrict ankle mechanics. Because the fibula lies just beneath the skin along the lateral leg, retained hardware can also produce localized irritation. Documentation should note the specific fixation construct removed and confirm the ankle mortise remains stable afterward.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.

Commonly Confused With

RevisionRevision is the most common point of confusion, since both involve existing hardware; Revision applies when a malfunctioning or displaced device is corrected or adjusted in place rather than taken out entirely.
ChangeChange is distinct because it captures removing a device and inserting a similar one through the same access site in one continuous procedure, most often for external fixation pins, rather than a permanent extraction.
ExtirpationExtirpation is unrelated in intent but sometimes confused when hardware fragments or broken screw pieces are retrieved rather than an intact device.