ICD-10-PCS Billable Code

02PY03Z

Removal Great Vessel to No Qualifier with Infusion Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System2 Heart and Great Vessels
OperationP Removal
Body PartY Great Vessel
Approach0 Open
Device3 Infusion Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal covers taking out a device that was previously placed in the heart or a great vessel, such as a pacemaker lead, a prosthetic valve ring, a vascular occluder, or an intra-aortic balloon pump catheter. This is not a procedure aimed at treating the underlying heart tissue; it is specifically about extracting hardware that no longer needs to be there, whether because it has failed, become infected, or served its temporary purpose.

Situations that call for this include lead extraction when a pacing wire is infected or malfunctioning, removal of a temporary mechanical circulatory support device once a patient stabilizes, or taking out a closure device that migrated or failed to seat properly. The procedure can be as simple as withdrawing a catheter at the bedside or as involved as an open surgical extraction of a chronically embedded lead.

Anatomy & Axis Detail

Great Vessel

Removal from a great vessel refers to extracting a previously placed device or foreign material, such as a stent, an occluder device, or a vascular access catheter component, from one of the great vessels rather than to any excision of the vessel wall. Great vessels encompass the aorta and its major branches along with the pulmonary arteries and veins and venae cavae, so the specific vessel involved should be clear from the operative documentation even though this code applies broadly across the group. Because implanted vascular devices can become endothelialized or adherent to the intima over time, their extraction may require careful dissection, and if the vessel requires subsequent repair after device removal, that repair should be captured with a separate code rather than folded into the removal itself.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Infusion Device

Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.

Coding & Documentation

Coders need documentation identifying exactly what device is being removed and confirming that nothing is being put in its place during the same operative episode - if a new device replaces the old one, the case is coded as Replacement or Insertion/Removal combination coding instead of Removal alone. The approach matters too: a lead pulled out through its existing venous entry site is coded differently than one requiring an open thoracotomy for extraction. A frequent error is coding Removal for routine adjustment or repositioning of a device that stays in the body, which instead falls under Revision.

Commonly Confused With

RevisionRevision is the procedure most often mixed up with Removal; Revision corrects, adjusts, or repositions a device that remains in place, while Removal takes it out entirely.
ReplacementReplacement is also closely linked, since removing an old device and inserting a new one in the same session is common practice, but that combined scenario is captured under the Replacement root operation rather than as a standalone Removal, unless coding guidelines direct separate capture of each component.