0SPB09Z
Removal Hip Joint, Left to No Qualifier with Liner, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | S Lower Joints |
| Operation | P Removal |
| Body Part | B Hip Joint, Left |
| Approach | 0 Open |
| Device | 9 Liner |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in a lower joint, such as internal fixation hardware, a spacer, drainage tubing, or an external fixator frame. These procedures are performed once the device has served its purpose - for example, after a fracture has healed and screws are no longer needed - or when a device is causing pain, infection, or mechanical irritation and needs to come out. Removal can be a planned, staged part of treatment or an unplanned procedure prompted by a complication.
Because the device itself, not the joint tissue, is the focus, these procedures are typically less extensive than the original surgery that placed the device, though scar tissue and bony ingrowth around older hardware can make removal technically demanding.
Anatomy & Axis Detail
Hip Joint, Left
The left hip joint mirrors its right-sided counterpart as a deep ball-and-socket articulation between the femoral head and acetabulum, bearing substantial load during standing and ambulation. Removal at this joint addresses retained cement, hardware fragments, or wear debris left within the joint space following a prior left-sided arthroplasty or fixation procedure, without disturbing the joint's native or prosthetic components. Deep soft tissue coverage over the hip means the surgical approach for retrieval often parallels that of a revision arthroplasty, and cross-sectional imaging typically guides the surgeon to the material's exact location before the procedure. Laterality documentation is essential here, as many patients undergo bilateral hip procedures over time and the left and right joints are coded independently.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Liner
A Liner in Medical and Surgical procedures is an insert placed within a prosthetic component, commonly the polyethylene or ceramic sleeve fitted inside an acetabular cup during hip arthroplasty, providing a wear surface between the shell and femoral head. It is typically part of a modular replacement rather than the entire joint substitute. It differs from a Resurfacing Device, which caps existing bone surfaces rather than lining an implanted shell.
Coding & Documentation
The operative note must identify the specific device being taken out and confirm nothing is being put in its place; if a new device replaces the old one, the more specific combination root operation (such as Revision) may apply instead of a plain Removal. The body part coded is the joint from which the device is taken, using the device's original insertion site. A recurring error is coding Removal when hardware is being exchanged for a different device during the same procedure, which should instead be captured as Revision, or when the device is being taken out specifically because it failed, which some coders mistakenly still classify simply as Removal without checking whether Revision criteria are met.