ICD-10-PCS Billable Code

0SP437Z

Removal Lumbosacral Disc to No Qualifier with Autologous Tissue Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemS Lower Joints
OperationP Removal
Body Part4 Lumbosacral Disc
Approach3 Percutaneous
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures take out a device that was previously placed in a lower joint, such as internal fixation hardware, a spacer, drainage tubing, or an external fixator frame. These procedures are performed once the device has served its purpose - for example, after a fracture has healed and screws are no longer needed - or when a device is causing pain, infection, or mechanical irritation and needs to come out. Removal can be a planned, staged part of treatment or an unplanned procedure prompted by a complication.

Because the device itself, not the joint tissue, is the focus, these procedures are typically less extensive than the original surgery that placed the device, though scar tissue and bony ingrowth around older hardware can make removal technically demanding.

Anatomy & Axis Detail

Lumbosacral Disc

The lumbosacral disc lies at the L5-S1 junction, the most caudal intervertebral disc and one of the most common sites for herniation given the shear forces generated where the mobile lumbar spine meets the fixed sacrum. Removal at this level refers to extracting a device or foreign material left in the disc space - retained fragments of a prior implant, migrated fusion cage material, or extruded cement - rather than excising native disc tissue. Because the L5-S1 level sits deep in the pelvis with the great vessels and sacral nerve roots close at hand, retrieving material here can be technically demanding and typically follows imaging that confirms the object's position relative to these structures. Precise documentation of the L5-S1 level distinguishes this procedure from removal at higher lumbar disc levels.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

The operative note must identify the specific device being taken out and confirm nothing is being put in its place; if a new device replaces the old one, the more specific combination root operation (such as Revision) may apply instead of a plain Removal. The body part coded is the joint from which the device is taken, using the device's original insertion site. A recurring error is coding Removal when hardware is being exchanged for a different device during the same procedure, which should instead be captured as Revision, or when the device is being taken out specifically because it failed, which some coders mistakenly still classify simply as Removal without checking whether Revision criteria are met.

Commonly Confused With

RevisionRemoval is closely related to Revision, and the distinction hinges on whether a malfunctioning or displaced device is simply corrected in place (Revision) or entirely taken out without replacement (Removal).
ReplacementIt is also distinct from Replacement, which involves taking out an existing device or tissue and putting in a new one to serve the same function.