ICD-10-PCS Billable Code

0WP60KZ

Removal Neck to No Qualifier with Nonautologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemW Anatomical Regions, General
OperationP Removal
Body Part6 Neck
Approach0 Open
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

This Removal family describes taking out a device that was previously placed in or on a general anatomical region - drains, packing, external fixation devices, or other hardware not tied to a single named organ or bone. It's used when a device has finished its job (a drain removed once output has resolved) or needs to come out for another reason, such as infection or patient intolerance, without anything being put in its place at that encounter.

Because "anatomical regions, general" spans areas like the abdominal wall, chest wall, or an extremity as a whole rather than a specific organ, this family picks up device removals that don't map cleanly to a more specific body system. It's a routine, often bedside or minor-procedure-level event rather than major surgery, though removal of some devices (like external fixators) can itself require anesthesia and operative time.

Anatomy & Axis Detail

Neck

The neck region contains the airway, major vessels, cervical spine, and numerous soft tissue planes, making it a common site for temporary devices during trauma or postoperative care. Removal here refers to extracting items such as a tracheostomy tube holder apparatus, a cervical drain, or external fixation hardware stabilizing a cervical spine injury, once no longer clinically necessary. The neck's dense concentration of vital structures, including the carotid vessels and jugular veins, means device withdrawal requires attention to avoid disrupting nearby anatomy, particularly when drains have been tunneled near major vessels. This code applies at the general neck region level when the device does not correspond to a single more specific anatomical structure within the neck.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Documentation needs to clearly identify the device being removed, the general region it was placed in, and confirm nothing is being implanted to replace it during that same encounter - if a new device goes in at the same time, the case usually needs a Removal and a separate Insertion/Replacement code, or a single Revision or Replacement code depending on what's documented. Coders should also verify whether the removal is being done as a stand-alone procedure or as an incidental step of a bigger operation, since incidental removal of a device to access the surgical field usually isn't coded separately.

A frequent mistake is coding Removal when the device is actually being exchanged for a new one in the same region; that scenario is typically Replacement, not Removal followed by nothing. Another common error is applying a general-region Removal code when the device actually belongs to a specific body system with its own removal code.

Commonly Confused With

RevisionRevision (0WW) is easily confused with Removal because both deal with existing devices, but Revision corrects or adjusts a device that stays in place, while Removal takes the device out entirely.
ReplacementReplacement is the other frequent mix-up: if an old device is taken out and a new one put in during the same operative episode, that combined action is Replacement, not a standalone Removal.