0QPD45Z
Removal Patella, Right to No Qualifier with External Fixation Device, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | P Removal |
| Body Part | D Patella, Right |
| Approach | 4 Percutaneous Endoscopic |
| Device | 5 External Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.
Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.
Anatomy & Axis Detail
Patella, Right
The right patella is the sesamoid bone embedded within the quadriceps tendon that protects the knee joint and enhances extensor mechanism leverage, and it may carry tension band wires, screws, or cerclage hardware placed to fix a patellar fracture. Removal at this site involves extracting such hardware, often performed once the fracture has healed, when wires or screws become palpable and irritating beneath the thin overlying soft tissue, or when infection develops around the implant. Because the patella sits directly under the skin with minimal soft tissue coverage, retained hardware is a frequent source of symptomatic prominence, making removal a relatively common follow-up procedure. Documentation should confirm laterality and specify the device extracted, distinguishing this clearly from any partial patellectomy, which would be reported under a different root operation.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: External Fixation Device
This is the general external fixation device value, used when pins or wires anchored in bone are connected to a stabilizing frame outside the body to hold a fracture or joint in position, without specifying a more particular frame configuration. It contrasts with the more specific External Fixation Device subtypes - Monoplanar, Ring, Hybrid, and Limb Lengthening - which describe the frame's geometry or added lengthening function.
Coding & Documentation
Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.