0WPN03Z
Removal Perineum, Female to No Qualifier with Infusion Device, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | W Anatomical Regions, General |
| Operation | P Removal |
| Body Part | N Perineum, Female |
| Approach | 0 Open |
| Device | 3 Infusion Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
This Removal family describes taking out a device that was previously placed in or on a general anatomical region - drains, packing, external fixation devices, or other hardware not tied to a single named organ or bone. It's used when a device has finished its job (a drain removed once output has resolved) or needs to come out for another reason, such as infection or patient intolerance, without anything being put in its place at that encounter.
Because "anatomical regions, general" spans areas like the abdominal wall, chest wall, or an extremity as a whole rather than a specific organ, this family picks up device removals that don't map cleanly to a more specific body system. It's a routine, often bedside or minor-procedure-level event rather than major surgery, though removal of some devices (like external fixators) can itself require anesthesia and operative time.
Anatomy & Axis Detail
Perineum, Female
In the female perineum, the area between the vulva and anus, devices removed typically include drains placed after obstetric repair, perineal reconstruction, or surgery for pelvic organ prolapse, as well as occasional mesh or suture material used in pelvic floor procedures that has eroded or become symptomatic. Removal here is coded when the device or material sits in the perineal soft tissue itself rather than in the vagina or a deeper pelvic structure. Given the perineum's role in continence and its proximity to the anal sphincter, careful attention is paid to avoiding injury to surrounding musculature during extraction, and healing is often monitored closely afterward given the region's exposure to moisture and friction during normal activity.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Infusion Device
Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.
Coding & Documentation
Documentation needs to clearly identify the device being removed, the general region it was placed in, and confirm nothing is being implanted to replace it during that same encounter - if a new device goes in at the same time, the case usually needs a Removal and a separate Insertion/Replacement code, or a single Revision or Replacement code depending on what's documented. Coders should also verify whether the removal is being done as a stand-alone procedure or as an incidental step of a bigger operation, since incidental removal of a device to access the surgical field usually isn't coded separately.
A frequent mistake is coding Removal when the device is actually being exchanged for a new one in the same region; that scenario is typically Replacement, not Removal followed by nothing. Another common error is applying a general-region Removal code when the device actually belongs to a specific body system with its own removal code.