0QP13JZ
Removal Sacrum to No Qualifier with Synthetic Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | P Removal |
| Body Part | 1 Sacrum |
| Approach | 3 Percutaneous |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.
Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.
Anatomy & Axis Detail
Sacrum
The sacrum is the large triangular bone formed by fused sacral vertebrae that connects the spine to the pelvis and commonly serves as an anchor point for spinopelvic fixation hardware, such as iliosacral screws or sacral rod attachments. Removal at this site refers to extracting a previously placed device, whether due to painful hardware prominence, mechanical failure, infection around the implant, or because temporary fixation is no longer needed once fusion has consolidated. The sacrum's dense cortical bone and its relationship to the sacral nerve roots and presacral vasculature make hardware extraction technically demanding, often requiring the same posterior approach used for the original placement. Coding should reflect only the device extraction, specifying the sacrum as the site, and should not be confused with removal of bone tissue itself, which falls under a different root operation.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.