ICD-10-PCS Billable Code

0VP87JZ

Removal Scrotum and Tunica Vaginalis to No Qualifier with Synthetic Substitute, Via Natural or Artificial Opening Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemV Male Reproductive System
OperationP Removal
Body Part8 Scrotum and Tunica Vaginalis
Approach7 Via Natural or Artificial Opening
DeviceJ Synthetic Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures in this family involve taking out a device that was previously placed in a structure of the male reproductive system, such as a penile prosthesis, testicular prosthesis, or a drain, rather than treating native tissue. These are performed when a device has served its purpose, malfunctioned, become infected, or needs to be exchanged for a different device.

Patients encounter these procedures most often after a prior implant surgery, such as removal of a penile implant due to mechanical failure, erosion, or infection, or removal of a testicular prosthesis that was placed after orchiectomy. Depending on the reason for removal, a new device may or may not be placed during the same operative session, which affects how the encounter is coded overall.

Anatomy & Axis Detail

Scrotum and Tunica Vaginalis

The scrotum and tunica vaginalis are coded together because the tunica vaginalis is the serous membrane lining the inner scrotal wall and directly investing the testis, and removal of both is typically performed for extensive scrotal skin disease, such as Fournier's gangrene requiring debridement beyond viable tissue, scrotal cancer, or chronic hydrocele with thickened, calcified tunica that cannot be adequately treated by drainage alone. Because the scrotal skin and its internal serous lining are structurally and functionally linked, surgeons removing diseased tunica often must also excise overlying scrotal skin to achieve adequate margins or wound closure, making the combined body part value appropriate. Documentation should specify that both the scrotal wall and the tunica investing layer were excised, as isolated tunica vaginalis procedures, such as hydrocelectomy alone, are captured under different, more limited codes.

Approach: Via Natural or Artificial Opening

Via Natural or Artificial Opening means the instrument reaches the target site by passing through an existing body orifice, such as the mouth or urethra, or a surgically created opening like a stoma, without additional incision or scope guidance. It is distinguished from the Endoscopic variant by the absence of a visualizing scope, and from External by actually traversing into the body through that opening.

Device: Synthetic Substitute

Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.

Coding & Documentation

A Removal code is assigned only when a device is being taken out and documentation confirms no new device is being put in through the same procedure; if a device is removed and immediately replaced, coders instead consider whether Revision or a Removal-plus-Insertion combination better reflects what was documented. The operative note should name the specific device removed, such as inflatable penile prosthesis components or a testicular implant, and confirm complete extraction.

A common mistake is coding Removal when the physician actually performed a Revision, which corrects or adjusts a malfunctioning device without full removal and replacement, or when a device is removed and a new one is placed in the same operative episode, which requires reporting both Removal and Insertion rather than Removal alone. Coders should also verify the body part reflects where the device was located rather than the device type itself.

Commonly Confused With

RevisionRemoval is frequently confused with Revision, since both address problems with an existing device, but Revision corrects, adjusts, or partially replaces components in place while Removal takes the device out entirely.
InsertionIt is also distinguished from Insertion, which places a new device without removing an old one, and situations involving both an old device coming out and a new one going in require separate Removal and Insertion codes rather than a single combined code.