ICD-10-PCS Billable Code

0RPJ3JZ

Removal Shoulder Joint, Right to No Qualifier with Synthetic Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemR Upper Joints
OperationP Removal
Body PartJ Shoulder Joint, Right
Approach3 Percutaneous
DeviceJ Synthetic Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures on the upper joints take out a device that was previously placed in the joint during an earlier operation, without putting anything else in its place. This covers situations like extracting hardware such as pins, screws, or wires used for a prior fracture repair once the bone has healed, removing an infected or loosened joint spacer, or taking out sutures, anchors, or other fixation devices that are no longer needed or are causing problems.

These procedures are performed when a device has served its purpose, has failed, is causing pain or irritation, or has become infected and needs to come out before any further treatment can proceed.

Anatomy & Axis Detail

Shoulder Joint, Right

The right shoulder joint is the glenohumeral articulation, a highly mobile ball-and-socket joint stabilized by the rotator cuff, labrum, and capsule, and it frequently receives implanted devices such as suture anchors, arthroscopic fixation hardware, or spacers used in staged infection management. Removal refers to extracting one of these previously placed devices without substituting a new one, a scenario distinct from revision arthroplasty where a prosthetic component is exchanged. Because the joint has extensive soft tissue coverage and a large capsule, retrieval of hardware can range from a simple arthroscopic maneuver for a loose anchor to an open procedure for deeper fixation. Documentation should identify the specific device taken out and confirm that no replacement component was implanted in the same operative session.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Synthetic Substitute

Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.

Coding & Documentation

Coding this family requires documentation that a device is being taken out and that nothing is being put in its place during the same operative episode - if a new device is implanted after removal, the procedure is coded instead as Replacement or Revision depending on what happened to the joint itself. The device type and its original purpose should be clear in the note to support the correct device value.

A common error is coding Removal for hardware taken out during a revision arthroplasty, when the removal of an old component and insertion of a new one in the same joint at the same session should instead be captured as a single Replacement procedure. Coders also sometimes overlook that removal of a device from a joint accompanied by repair of joint damage caused by that device requires an additional Repair or Revision code for the corrected tissue.

Commonly Confused With

RevisionRemoval is often confused with Revision, which applies when a previously placed device is being corrected or adjusted in position rather than simply taken out - Revision is used when the device stays in the body in an altered state.
ReplacementIt is also confused with Replacement when a new implant goes in at the same encounter as the old one comes out, since both device changes are captured under the single Replacement root operation rather than as separate Removal and Insertion codes.