ICD-10-PCS Billable Code

0RPF48Z

Removal Sternoclavicular Joint, Left to No Qualifier with Spacer, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemR Upper Joints
OperationP Removal
Body PartF Sternoclavicular Joint, Left
Approach4 Percutaneous Endoscopic
Device8 Spacer
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures on the upper joints take out a device that was previously placed in the joint during an earlier operation, without putting anything else in its place. This covers situations like extracting hardware such as pins, screws, or wires used for a prior fracture repair once the bone has healed, removing an infected or loosened joint spacer, or taking out sutures, anchors, or other fixation devices that are no longer needed or are causing problems.

These procedures are performed when a device has served its purpose, has failed, is causing pain or irritation, or has become infected and needs to come out before any further treatment can proceed.

Anatomy & Axis Detail

Sternoclavicular Joint, Left

The left sternoclavicular joint mirrors its right-sided counterpart as the sole bony connection between the clavicle and the trunk, stabilized by an intra-articular fibrocartilage disc and dense capsular ligaments. Removal at this site typically involves extracting hardware such as suture anchors, plates, or pin fixation that was implanted to manage instability, infection, or post-traumatic reconstruction, without placing a substitute device. Surgeons approaching this joint must work close to the great vessels and superior mediastinum on the left side, which can influence how implants were originally secured and how cautiously they are later withdrawn. Documentation should clearly state that the procedure is a pure device extraction rather than a joint replacement or revision, since retained wires or broken hardware fragments occasionally require separate mention if only partially retrievable.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Spacer

In Medical and Surgical procedures, a Spacer is a temporary, non-articulating device left in a joint or space after a component is removed, most often an antibiotic-impregnated cement block placed during a staged joint revision to control infection while preserving space and alignment. It is not intended to move like a real joint. It differs from an Articulating Spacer, which is shaped to permit some motion during the interim period, and from a permanent Synthetic Substitute.

Coding & Documentation

Coding this family requires documentation that a device is being taken out and that nothing is being put in its place during the same operative episode - if a new device is implanted after removal, the procedure is coded instead as Replacement or Revision depending on what happened to the joint itself. The device type and its original purpose should be clear in the note to support the correct device value.

A common error is coding Removal for hardware taken out during a revision arthroplasty, when the removal of an old component and insertion of a new one in the same joint at the same session should instead be captured as a single Replacement procedure. Coders also sometimes overlook that removal of a device from a joint accompanied by repair of joint damage caused by that device requires an additional Repair or Revision code for the corrected tissue.

Commonly Confused With

RevisionRemoval is often confused with Revision, which applies when a previously placed device is being corrected or adjusted in position rather than simply taken out - Revision is used when the device stays in the body in an altered state.
ReplacementIt is also confused with Replacement when a new implant goes in at the same encounter as the old one comes out, since both device changes are captured under the single Replacement root operation rather than as separate Removal and Insertion codes.