ICD-10-PCS Billable Code

0SPH03Z

Removal Tarsal Joint, Right to No Qualifier with Infusion Device, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemS Lower Joints
OperationP Removal
Body PartH Tarsal Joint, Right
Approach0 Open
Device3 Infusion Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures take out a device that was previously placed in a lower joint, such as internal fixation hardware, a spacer, drainage tubing, or an external fixator frame. These procedures are performed once the device has served its purpose - for example, after a fracture has healed and screws are no longer needed - or when a device is causing pain, infection, or mechanical irritation and needs to come out. Removal can be a planned, staged part of treatment or an unplanned procedure prompted by a complication.

Because the device itself, not the joint tissue, is the focus, these procedures are typically less extensive than the original surgery that placed the device, though scar tissue and bony ingrowth around older hardware can make removal technically demanding.

Anatomy & Axis Detail

Tarsal Joint, Right

The right tarsal joints link the calcaneus, talus, navicular, and cuboid, forming the subtalar and midfoot articulations that translate ankle motion into the inversion and eversion needed for walking on uneven ground. Removal here means taking out a nonbiological device, such as an arthrodesis plate, screw construct, or spacer placed during a prior fusion or reconstruction, without cutting into new joint surfaces. Surgeons encounter this when hardware becomes symptomatic, migrates, loosens, or is simply staged for removal after bone healing is confirmed on imaging. Because the tarsal complex bears substantial load during stance and push-off, retained hardware can produce localized pain, irritation of overlying tendons, or restricted motion, making device removal a common finishing step following flatfoot correction, subtalar fusion, or trauma fixation in this region.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Infusion Device

Infusion Device denotes a device left in place to deliver medication, fluids, or other substances into a body part over time, such as an intrathecal or epidural pump. It is distinct from devices that merely monitor or mechanically support tissue, since its function is ongoing pharmacologic or fluid delivery rather than structural replacement. Common placements include the spinal canal, peritoneal cavity, and vascular access sites.

Coding & Documentation

The operative note must identify the specific device being taken out and confirm nothing is being put in its place; if a new device replaces the old one, the more specific combination root operation (such as Revision) may apply instead of a plain Removal. The body part coded is the joint from which the device is taken, using the device's original insertion site. A recurring error is coding Removal when hardware is being exchanged for a different device during the same procedure, which should instead be captured as Revision, or when the device is being taken out specifically because it failed, which some coders mistakenly still classify simply as Removal without checking whether Revision criteria are met.

Commonly Confused With

RevisionRemoval is closely related to Revision, and the distinction hinges on whether a malfunctioning or displaced device is simply corrected in place (Revision) or entirely taken out without replacement (Removal).
ReplacementIt is also distinct from Replacement, which involves taking out an existing device or tissue and putting in a new one to serve the same function.