ICD-10-PCS Billable Code

0QPM07Z

Removal Tarsal, Left to No Qualifier with Autologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemQ Lower Bones
OperationP Removal
Body PartM Tarsal, Left
Approach0 Open
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.

Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.

Anatomy & Axis Detail

Tarsal, Left

The left tarsal bones make up the hindfoot and midfoot, and Removal procedures here address hardware left from calcaneal fracture fixation, subtalar or midfoot arthrodesis, or reconstructive flatfoot surgery. Fixation across these small, irregularly shaped bones often uses screws or plates positioned close to weight-bearing surfaces of the sole, so retained hardware frequently becomes symptomatic with prolonged standing or tight footwear even after solid bony union. Screws that cross a fusion site are sometimes deliberately left permanently, while those causing joint impingement or soft-tissue irritation are removed electively. Given the close proximity of multiple tarsal bones, precise identification of the specific bone from which the device is extracted matters for accurate documentation, since the tarsal group covers several anatomically distinct structures.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.

Commonly Confused With

RevisionRevision is the most common point of confusion, since both involve existing hardware; Revision applies when a malfunctioning or displaced device is corrected or adjusted in place rather than taken out entirely.
ChangeChange is distinct because it captures removing a device and inserting a similar one through the same access site in one continuous procedure, most often for external fixation pins, rather than a permanent extraction.
ExtirpationExtirpation is unrelated in intent but sometimes confused when hardware fragments or broken screw pieces are retrieved rather than an intact device.