0QPH44Z
Removal Tibia, Left to No Qualifier with Internal Fixation Device, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | P Removal |
| Body Part | H Tibia, Left |
| Approach | 4 Percutaneous Endoscopic |
| Device | 4 Internal Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.
Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.
Anatomy & Axis Detail
Tibia, Left
The left tibia bears the majority of load transmitted through the lower leg, and Removal procedures here address hardware implanted for fracture fixation, correctional osteotomy, or external fixation during limb reconstruction. Plates and intramedullary nails may remain for a year or more because tibial cortical bone remodels slowly, particularly in the distal third where blood supply is comparatively limited. Indications for removal include persistent pain over subcutaneous hardware, painful hardware near the ankle mortise, planned revision surgery, or infection at pin tracts from a prior external fixator. Because the tibial shaft is directly palpable under thin anteromedial skin, retained hardware is often symptomatic even after solid union, making elective device removal a routinely performed operation once fracture healing is radiographically confirmed.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Internal Fixation Device
Internal fixation device is the general value for hardware such as plates, screws, or rods placed within the body to stabilize bone or joint, used when a more specific configuration is not indicated. It stands in contrast to the named subtypes - Rigid Plate, Intramedullary, Sustained Compression, and Intramedullary Limb Lengthening - which specify how the hardware achieves stabilization.
Coding & Documentation
Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.