0QPG34Z
Removal Tibia, Right to No Qualifier with Internal Fixation Device, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | Q Lower Bones |
| Operation | P Removal |
| Body Part | G Tibia, Right |
| Approach | 3 Percutaneous |
| Device | 4 Internal Fixation Device |
| Qualifier | Z No Qualifier |
Operation Definition
Taking out or off a device from a body part
Procedure Overview
Removal procedures take out a device that was previously placed in or on a lower bone - hardware such as plates, screws, rods, pins, external fixator components, or spacers used in the pelvis, femur, tibia, fibula, patella, or foot bones. These devices are typically inserted to stabilize a fracture, hold a bone graft, or support a joint during healing, and removal happens once that purpose has been served or if the device is causing a problem.
Reasons for removal vary widely. Hardware may simply be scheduled for extraction after a fracture has healed, especially in children whose growing bones can be irritated by permanent implants. In other cases the device is removed because it has become infected, has loosened, is causing pain from irritating overlying soft tissue, or is interfering with a later procedure such as a joint replacement.
Anatomy & Axis Detail
Tibia, Right
The right tibia is the primary weight-bearing bone of the lower leg, and Removal at this site typically involves extracting intramedullary nails, locking plates, screws, or external fixator pins placed after fracture, osteotomy, or limb-lengthening procedures. Tibial fixation is often left in place for extended periods given the bone's slow healing in the distal third, so removal decisions weigh the risk of refracture through old screw holes against symptoms such as pain, hardware irritation near the subcutaneous anteromedial surface, or infection around fixator pin sites. Intramedullary nail extraction requires specialized extraction instruments to engage the proximal locking mechanism. The procedure is coded as Removal only when the device itself is taken out, distinct from any concurrent debridement of surrounding bone or soft tissue.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Internal Fixation Device
Internal fixation device is the general value for hardware such as plates, screws, or rods placed within the body to stabilize bone or joint, used when a more specific configuration is not indicated. It stands in contrast to the named subtypes - Rigid Plate, Intramedullary, Sustained Compression, and Intramedullary Limb Lengthening - which specify how the hardware achieves stabilization.
Coding & Documentation
Coders assign Removal when documentation confirms a device is being taken out and not replaced with another device during the same operative episode - if a new device goes in at the same site, the procedure is Change or a combination of Removal and another root operation such as Insertion, not Removal alone. The device type and the specific bone it was removed from both need to be identifiable from the operative note. A common error is coding Removal for hardware that is only being adjusted or repositioned rather than fully extracted, or overlooking that the removal of a device is bundled into a broader procedure when substantial additional work, like bone repair, is performed at the same site.
