ICD-10-PCS Billable Code

0TP94CZ

Removal Ureter to No Qualifier with Extraluminal Device, Percutaneous Endoscopic Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemT Urinary System
OperationP Removal
Body Part9 Ureter
Approach4 Percutaneous Endoscopic
DeviceC Extraluminal Device
QualifierZ No Qualifier

Operation Definition

Taking out or off a device from a body part

Procedure Overview

Removal procedures in the urinary system take out a device that a clinician previously placed to support, drain, or monitor the kidneys, ureters, bladder, or urethra. Common examples include pulling a ureteral stent that was placed to relieve an obstruction, removing a nephrostomy tube once a kidney has healed enough to drain on its own, or taking out a suprapubic catheter or artificial urinary sphincter component.

These procedures are done when the device has finished its job, has failed, or is causing a complication such as infection or encrustation. Patients may have the device removed at bedside, in an outpatient clinic, or in an operating room depending on how it was originally placed and whether tissue has grown around it.

Removal is distinct from taking out diseased or damaged native tissue - it applies only to previously implanted hardware.

Anatomy & Axis Detail

Ureter

Removal from the ureter refers to extracting a device or foreign material placed within this tube, most commonly a ureteral stent inserted to maintain patency after stone treatment, surgery, or to bypass an obstruction, though it can also apply to retrieval of a migrated foreign body. Stents are typically removed cystoscopically once their therapeutic purpose has been served, a routine outpatient procedure distinct from any manipulation of the ureteral wall itself. Because stents can be placed unilaterally or bilaterally and left indwelling for varying durations depending on the underlying condition, documentation should specify which ureter the device is being removed from and confirm that no ureteral tissue was incised or excised during the encounter, which would instead be captured under a different root operation such as extirpation or excision.

Approach: Percutaneous Endoscopic

Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.

Device: Extraluminal Device

Extraluminal Device describes a device positioned on the outside surface of a tubular or hollow body part rather than within its lumen, such as a vascular banding or external stabilization device. It is the structural counterpart to Intraluminal Device, distinguished by its external placement relative to the vessel or duct wall rather than sitting inside the passageway itself.

Coding & Documentation

A coder assigns a Removal code from this family when documentation confirms a device is being taken out and not replaced with a new one in the same session. The operative or procedure note should name the specific device (stent, catheter, drainage tube, sphincter cuff, etc.) and the approach used to retrieve it, since that determines the approach character.

The most frequent error is coding Removal when the device was actually exchanged for a new one in the same encounter; if a stent is pulled and a new stent is placed immediately, that combination is captured differently and simple Removal undercodes the encounter. Another common miss is failing to code Removal separately when it occurs incidentally during a different primary procedure, or conversely coding a bedside catheter pull that never required a procedure to begin with.

Commonly Confused With

ExtirpationRemoval is often confused with Extirpation, which takes out solid matter such as a stone or clot rather than a device.
RevisionIt is also confused with Revision, which corrects or adjusts a device left in place rather than taking it out entirely.