0PQ73ZZ
Repair Glenoid Cavity, Right to No Qualifier with No Device, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | Q Repair |
| Body Part | 7 Glenoid Cavity, Right |
| Approach | 3 Percutaneous |
| Device | Z No Device |
| Qualifier | Z No Qualifier |
Operation Definition
Restoring, to the extent possible, a body part to its normal anatomic structure and function
Procedure Overview
This family covers surgical repair of the bones of the skull, face, ribs, sternum, and upper limbs - the clavicle, scapula, humerus, radius, ulna, and the small bones of the wrist and hand - when a fracture, crack, or other structural defect needs to be fixed but doesn't fit a more specific repair category like reposition or replacement. A surgeon might use this approach for a depressed skull fracture, a cracked sternum, a small chip fracture in a carpal bone, or a rib that needs stabilization after trauma.
The underlying goal is simply to restore the bone to something close to its normal shape and strength, using whatever technique the situation calls for - wiring, plating, bone grafting, or direct suturing of periosteum. It's often the option coders reach for when nothing else in the root operation list quite matches what the operative note describes, since it functions as the default "fix it" category for bones.
Anatomy & Axis Detail
Glenoid Cavity, Right
The glenoid cavity is the shallow, pear-shaped socket on the lateral scapula that articulates with the humeral head to form the shoulder joint, and its cartilage-lined rim is what keeps the joint stable through such a wide arc of motion. Fractures or erosion of the right glenoid rim often follow a shoulder dislocation or direct impact, and repair is coded when this articular surface and its bony rim are restored to normal contour without replacing the joint surface or fixing fragments with hardware left in place, such as correcting a minor rim fracture. Because even small glenoid defects can predispose the shoulder to recurrent instability, the documentation should make clear that the procedure addressed the socket itself rather than the scapular body or the humeral side of the joint.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Coding & Documentation
A coder assigns from this family when the operative note describes correcting a bone defect without moving a displaced fragment back into alignment (that's reposition) or removing and replacing tissue (that's replacement or supplement). Documentation should specify the exact bone and any device or graft material used, since that affects the qualifier and device value. The most common assignment error is defaulting to repair when the surgeon actually performed a reposition of a displaced fracture fragment - the two are frequently confused because both involve fractures. Another frequent mistake is coding repair when a bone graft was used to reinforce rather than restore the bone, which should instead be captured as supplement.
