ICD-10-PCS Billable Code

0FQ23ZZ

Repair Liver, Left Lobe to No Qualifier with No Device, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemF Hepatobiliary System and Pancreas
OperationQ Repair
Body Part2 Liver, Left Lobe
Approach3 Percutaneous
DeviceZ No Device
QualifierZ No Qualifier

Operation Definition

Restoring, to the extent possible, a body part to its normal anatomic structure and function

Procedure Overview

Repair procedures in the liver, gallbladder, bile ducts, and pancreas address structural damage from trauma, surgical injury, or disease that doesn't require removing or replacing tissue, only restoring it to its normal form. Typical examples include suturing a lacerated liver after blunt abdominal trauma, closing a bile leak discovered after a prior cholecystectomy, or repairing a perforated gallbladder wall. Because Repair is the default root operation whenever no more specific term applies, it also captures a wide range of miscellaneous fixes that don't fit neatly into resection, replacement, or the other defined operations.

These procedures are performed to stop bleeding, prevent bile or pancreatic fluid from leaking into the abdominal cavity, and preserve as much functioning organ tissue as possible. Surgeons may operate emergently, as with a stab wound to the liver, or electively, as with closure of a chronic pancreatic fistula.

Anatomy & Axis Detail

Liver, Left Lobe

The left lobe of the liver is smaller than the right and lies across the midline in close proximity to the stomach and lesser omentum, a position that makes it more accessible surgically but also puts it at risk during upper abdominal trauma or adjacent gastric and esophageal procedures. Repair of this lobe addresses lacerations or parenchymal defects using direct suture closure, topical hemostatic agents, or fibrin sealants to achieve hemostasis and reapproximate the injured tissue. Because the left lobe's blood supply arises from the left branches of the portal triad and can vary anatomically, particularly in patients with a replaced left hepatic artery, awareness of this variant supply is relevant when repairing injuries near the hilum. Coding the left lobe specifically distinguishes this repair from procedures on the right lobe or on the liver considered as a whole.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Coding & Documentation

Coders assign a Repair code when the operative note describes suturing, patching without graft material, or otherwise closing a defect without removing or substituting tissue, and no other root operation more precisely describes the objective. The documentation should specify the organ involved and the nature of the defect being closed, since the qualifying body part character depends on exact anatomic location. A frequent error is defaulting to Repair when the physician actually performed a more specific procedure, such as excision of damaged tissue, which should instead be captured separately. Coders should also watch for cases where mesh, patch, or other material is used to reinforce the closure, since that shifts the case toward Supplement rather than Repair.

Commonly Confused With

SupplementRepair is easily confused with Supplement, which applies when biological or synthetic material is added to reinforce a structure rather than simply closing a defect with the body's own tissue.
ReplacementIt's also distinguished from Replacement, used when a device or graft physically takes over the function of the removed body part rather than reinforcing existing tissue, and from Resection, which removes tissue entirely rather than restoring it.