0NRF37Z
Replacement Ethmoid Bone, Right to No Qualifier with Autologous Tissue Substitute, Percutaneous Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | N Head and Facial Bones |
| Operation | R Replacement |
| Body Part | F Ethmoid Bone, Right |
| Approach | 3 Percutaneous |
| Device | 7 Autologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
Procedure Overview
Replacement procedures put in biological or synthetic material - such as a cranioplasty plate, custom facial implant, or bone graft - to physically take the place of all or part of a skull or facial bone that is missing, damaged, or was previously removed. This family is used when the goal is not just to fix the existing bone but to substitute new material for a portion that no longer serves its structural role.
Common reasons include reconstructing a skull defect left after a craniectomy for trauma or tumor, rebuilding an orbital floor after a blowout fracture, or restoring facial contour with a custom implant following cancer resection. Patients pursuing these procedures are typically working toward both functional protection of underlying structures, like the brain or eye, and restoration of facial appearance.
Anatomy & Axis Detail
Ethmoid Bone, Right
The right ethmoid bone sits between the orbits and nasal cavity, forming part of the medial orbital wall, the roof of the nasal cavity, and the cribriform plate through which olfactory nerve fibers pass into the cranial cavity. Its thin, honeycomb-like structure of air cells makes it particularly susceptible to destruction from sinonasal tumors, invasive fungal infection, or trauma, and replacement is considered when enough native bone has been lost that the separation between the nasal cavity, orbit, and anterior cranial fossa can no longer be maintained without reconstruction. Because the cribriform plate carries olfactory nerve filaments and lies adjacent to the dura, replacement in this region carries a meaningful risk of cerebrospinal fluid leak and olfactory disruption, requiring meticulous technique. The right-sided designation is important given the paired, non-fused nature of the ethmoid labyrinth and its close relationship to the right orbit and optic pathway.
Approach: Percutaneous
Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.
Device: Autologous Tissue Substitute
Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.
Coding & Documentation
Documentation should specify the material used, whether an autologous bone graft, titanium mesh, or synthetic implant, and confirm that it is taking the place of bone rather than merely reinforcing it. Coders need to identify the specific facial or cranial bone being replaced, since body part selection within this family is granular. A frequent error is coding Replacement when a graft is instead used to support a repair rather than substitute for missing bone, and another is confusing a temporary spacer or external fixation device, which does not qualify as replacement material, with a permanent implant.