0PRF4KZ
Replacement Humeral Shaft, Right to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Endoscopic Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | P Upper Bones |
| Operation | R Replacement |
| Body Part | F Humeral Shaft, Right |
| Approach | 4 Percutaneous Endoscopic |
| Device | K Nonautologous Tissue Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
Procedure Overview
Replacement procedures in the upper bones involve removing all or part of a bone in the skull, face, thorax, or upper limb and substituting it with a device or biological material that takes over its structural role. Cranioplasty with a synthetic plate after a skull defect, and prosthetic reconstruction of a portion of the humerus or clavicle following tumor removal, are typical examples.
These procedures are performed when a bone is too damaged, diseased, or absent to be repaired or repositioned, and the patient needs a physical substitute to maintain the shape of the skull or the mechanical function of a limb. The material can be a synthetic implant, such as titanium mesh or bone cement, or biological tissue, such as an allograft.
Anatomy & Axis Detail
Humeral Shaft, Right
The humeral shaft is the long diaphyseal segment of the upper arm bone lying between the proximal and distal metaphyses, providing attachment for the deltoid, biceps, and triceps while housing the radial nerve along its spiral groove. Right-sided replacement is performed for extensive segmental bone loss from open fracture nonunion, chronic osteomyelitis, or tumor resection, where an intercalary allograft, vascularized bone graft, or modular endoprosthetic segment restores the shaft's length and rotational alignment. The radial nerve's proximity along the posterior spiral groove makes nerve protection a recurring concern during dissection and graft placement. Coders should confirm that the procedure reconstructs a segment of the diaphysis itself rather than merely fixing an intact but fractured shaft.
Approach: Percutaneous Endoscopic
Percutaneous Endoscopic combines a puncture through skin or mucous membrane with insertion of an endoscope to visualize the procedure internally, as in laparoscopic cholecystectomy. It is distinguished from plain Percutaneous by the presence of scope-guided visualization, and from Via Natural or Artificial Opening Endoscopic by its route being a new puncture rather than an existing orifice or stoma.
Device: Nonautologous Tissue Substitute
Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.
Coding & Documentation
Coding from this family requires documentation that a body part was actually taken out and something physically put in its place, not simply reinforced. The device value must match the material used - synthetic versus autologous versus nonautologous tissue - so operative notes describing the graft source matter for accurate code selection. A recurring error is coding replacement when the native bone was left in place and only augmented, which belongs under supplement instead. Coders should also confirm whether the replaced segment is a full bone or only a portion, since this affects the body part value chosen.