04RF0JZ
Replacement Internal Iliac Artery, Left to No Qualifier with Synthetic Substitute, Open Approach
Procedural Specifications
| Clinical Axis | Detail Definition |
|---|---|
| Section | 0 Medical and Surgical |
| Body System | 4 Lower Arteries |
| Operation | R Replacement |
| Body Part | F Internal Iliac Artery, Left |
| Approach | 0 Open |
| Device | J Synthetic Substitute |
| Qualifier | Z No Qualifier |
Operation Definition
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
Procedure Overview
Replacement procedures in the lower arteries involve taking out a diseased or damaged arterial segment and putting in synthetic graft material or biological tissue to physically stand in for that piece of vessel. This is distinct from simply patching or reinforcing an artery, since the native segment is functionally substituted rather than preserved and bolstered.
A classic example is an aortobifemoral or femoral-popliteal graft placed after removing a severely diseased, occluded, or aneurysmal segment of artery, using a synthetic conduit such as Dacron or PTFE, or in some cases a harvested vein used as a full segmental replacement. Patients typically arrive at this procedure after conservative management or angioplasty has failed, or when an aneurysm poses a rupture risk that mandates excising the weakened wall.
Anatomy & Axis Detail
Internal Iliac Artery, Left
The left internal iliac artery supplies the pelvic organs, gluteal region, and perineal structures on the left side and, like its right-sided counterpart, branches quickly after leaving the common iliac artery, limiting the length of vessel available for open reconstruction. Replacement is most often performed when an aneurysm involving this segment threatens to rupture or when the artery must be reconstructed during extensive aortoiliac aneurysm repair to preserve pelvic perfusion and reduce the risk of ischemic complications such as buttock claudication or bowel ischemia. A short graft is typically anastomosed between the common iliac artery and the proximal hypogastric trunk to restore continuity. Because ligation is sometimes chosen instead when collateral flow is adequate, operative documentation should clearly indicate that an actual replacement conduit was placed rather than the vessel simply being tied off.
Approach: Open
Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.
Device: Synthetic Substitute
Synthetic Substitute designates a device made from manufactured, non-biologic material, such as mesh or prosthetic components, used to replace or augment a body part. It is distinguished from the two tissue substitute categories by its artificial composition, which carries different considerations for integration and long-term durability than biologic grafts.
Coding & Documentation
The operative report must clearly establish that a segment of native artery was excised or its function replaced, and that a graft or biological material took its place, distinguishing this from Bypass, where the diseased segment is left in place and a new route is constructed around it. Coders should identify the specific arterial body part value replaced and the device value representing the graft material, whether autologous, nonautologous, or synthetic.
A common error is coding a bypass graft as a Replacement when the original artery segment was left intact and simply routed around; another is failing to capture the correct device value when a combination of graft materials was used in a single reconstruction.
