ICD-10-PCS Billable Code

08RK3KZ

Replacement Lens, Left to No Qualifier with Nonautologous Tissue Substitute, Percutaneous Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body System8 Eye
OperationR Replacement
Body PartK Lens, Left
Approach3 Percutaneous
DeviceK Nonautologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

Procedure Overview

Replacement procedures in the eye involve putting in biological or synthetic material that physically takes the place of all or part of an ocular structure that can no longer perform its function. The most familiar example is intraocular lens implantation after cataract removal, where a clouded natural lens is replaced with an artificial lens to restore clear vision. Other examples include corneal transplantation using donor tissue and, less commonly, prosthetic replacement of orbital or eyelid structures following extensive tissue loss.

These procedures are performed when a body part is damaged beyond repair, diseased, or has degenerated to the point that its native function is permanently compromised. Replacement differs from patching or reinforcing an existing structure; the original tissue's role is essentially taken over by the implanted material, which is why these procedures are often the definitive, final step in restoring functional vision.

Anatomy & Axis Detail

Lens, Left

The left lens is the flexible, transparent structure behind the iris that adjusts focus by changing shape, and its replacement is performed chiefly in cataract surgery, where the opacified native lens is removed via phacoemulsification and a synthetic intraocular lens is placed within the capsular bag to restore clear vision. Preoperative biometric measurements determine the correct implant power for this specific eye, and the procedure may also address astigmatism or presbyopia depending on the lens type selected. Because the artificial lens physically substitutes for the excised native lens and assumes its refractive function, this is coded as Replacement rather than simple extraction. The left-eye designation is important clinically since cataract surgery is commonly staged between eyes, and prior right-eye outcomes may influence lens selection for this procedure.

Approach: Percutaneous

Percutaneous describes entry by needle or instrument puncture through the skin or mucous membrane to reach the site of the procedure, without cutting the tissue open or using a visualizing scope. It differs from Open in that the site itself is never exposed, and from Percutaneous Endoscopic in that no endoscope is used to see internal structures. Common examples include needle biopsies and injections.

Device: Nonautologous Tissue Substitute

Nonautologous Tissue Substitute refers to biologic material sourced from a donor or another species, such as an allograft or xenograft, used to replace a body part. It differs from Autologous Tissue Substitute by tissue origin outside the patient's own body, and from Synthetic Substitute by being biologic rather than manufactured material.

Coding & Documentation

Coders assign Replacement when documentation shows that a body part was removed or is being substituted by an implant, graft, or prosthetic device that assumes its function, most commonly seen in cataract surgery with intraocular lens placement or in penetrating and lamellar keratoplasty using donor corneal tissue. Operative notes need to specify what was taken out (if anything) and confirm the material inserted, since the qualifying body part value in the code depends on identifying the correct structure being replaced.

A common assignment mistake is coding intraocular lens insertion without pairing it with the appropriate cataract extraction code when both occurred in the same operative episode, since these are usually reported together as distinct procedures. Another error is misidentifying corneal transplant type, since full-thickness and partial-thickness grafts can carry different coding implications depending on documentation detail.

Commonly Confused With

SupplementReplacement is often confused with Supplement, since both involve adding material to the eye; the distinguishing factor is whether the added material takes over the entire function of a body part (Replacement) or merely reinforces an existing structure that continues to function on its own (Supplement).
ResectionIt also overlaps conceptually with Resection, since many Replacement procedures, like corneal transplant, begin with removal of damaged tissue before the graft is placed, but Resection alone does not capture the insertion of replacement material, so the coder must recognize when both elements are documented.