ICD-10-PCS Billable Code

0QRC07Z

Replacement Lower Femur, Left to No Qualifier with Autologous Tissue Substitute, Open Approach

Procedural Specifications

Clinical Axis Detail Definition
Section0 Medical and Surgical
Body SystemQ Lower Bones
OperationR Replacement
Body PartC Lower Femur, Left
Approach0 Open
Device7 Autologous Tissue Substitute
QualifierZ No Qualifier

Operation Definition

Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part

Procedure Overview

Replacement procedures put in biological or synthetic material that physically takes over the role of all or part of a lower bone. This includes structural bone grafts, cadaver bone allografts, and synthetic bone substitutes used to rebuild a portion of the pelvis, femur, tibia, fibula, or foot bones after tumor resection, severe trauma, or bone loss from infection.

These procedures are performed when a segment of bone is missing or so damaged that it can no longer support the body's structure or function on its own, and simply repairing or repositioning the remaining bone isn't enough. A patient who has had a tumor removed from the femoral shaft, for example, may need the resulting gap filled with a structural allograft to restore the bone's load-bearing capacity.

Anatomy & Axis Detail

Lower Femur, Left

The lower femur on the left, made up of the medial and lateral condyles and the surrounding metaphysis, forms the femoral half of the knee joint and bears the rolling contact load transmitted from the tibia during gait. When this bone is replaced, the procedure is most often the femoral component of knee arthroplasty, performed for advanced degenerative or inflammatory arthritis, post-traumatic joint destruction, avascular necrosis of the condyle, or failure of a previous implant requiring revision. The resected condylar surfaces are replaced with a shaped prosthetic component that preserves the femoral roll-back mechanism needed for deep flexion, and correct sizing and rotational positioning are critical to avoid patellar maltracking. Coders should confirm whether the tibial plateau and patellar surface were replaced concurrently, as each is reported under its own specific body part.

Approach: Open

Open approach means the surgeon cuts through skin, mucous membrane, or other tissue layers to physically expose the target site to view before performing the procedure. It gives direct visualization and hands-on access, distinguishing it from Percutaneous approaches where instruments pass through a small puncture without exposing the site. Open is typical for procedures needing wide access, such as most laparotomies.

Device: Autologous Tissue Substitute

Autologous Tissue Substitute identifies a device value where material harvested from the patient's own body, such as an autograft, is used to replace or reconstruct a body part. Its defining feature is tissue origin from the patient, setting it apart from Nonautologous Tissue Substitute, sourced from a donor or animal, and Synthetic Substitute, made of manufactured material.

Coding & Documentation

Documentation must describe material being put in that takes over the physical role of the bone segment - not material that merely reinforces existing bone, which would be Supplement instead. The type of graft or substitute material and the specific bone segment addressed both need to be clear in the operative note. A frequent error is coding Replacement when bone graft is used to fill a defect but the native bone structure is still largely intact and functional, which points toward Supplement rather than Replacement; another is confusing joint replacement procedures, which are coded to the Lower Joints body system, with bone-segment replacement coded here.

Commonly Confused With

SupplementSupplement is the closest and most frequently confused root operation, since both can involve grafting material into bone; the distinguishing factor is whether the material takes the place of a missing or resected bone segment (Replacement) or reinforces bone that is still structurally present (Supplement).
InsertionInsertion is distinct because it covers placing a device that doesn't physically substitute for bone tissue, such as a spacer.
RepositionReposition is unrelated in purpose, since it moves existing bone rather than replacing missing bone with new material.